Search results

  1. T

    Filter drain plug housing cracked; Next step...

    Yesterday, my 12-year old Waterway 60 sf DE filter drain plug was leaking pretty bad; with the filter off, I tightened it just a bit and must've cracked the housing for the drain plug; I've tried a hose clamp to provide some rigidity, but under pressure it's spurting water like a geyser. So...
  2. T

    Want to close, but pH continues to rise / FC & Polyquat

    Good morning. I've had the pool covered and running 5 hours per day for the last month. While I have been waiting for the water to drop below 60 degrees in order to close the FC level has been really consistent...was going down about 0.5 every 3-4 days while the water was warmer. During the...
  3. T

    Added 58% Calcium Hypo - pool went cloudy

    The pool has been on the Clorox bleach only diet for about 5 weeks. It looked great. My CH was at 225 and I want to get it up to 300/350 range. Since I have several left over pounds of Calcium Hypochlorite 57.8% I thought I would just use that for a few days instead of Clorox to treat the...
  4. T

    Last 10% on SLAM and prepping for the next problem(s). Stains and deterioration?

    I started a SLAM on 07/08 not because I could see algae but because I kept losing FC and couldn't see why. I have passed OCLT a few times only to fail it the next day when I tried to get 2 days in a row. This morning my drop was 0.5 as I tested at 20 FC last night (10 pm) and was at 19.5 (6...
  5. T

    New pressure gauge issue - installer issue

    Need suggestions please. I was taking apart 60sf DE filter and cleaning today...trying to finish a slam and trying to figure out why I am still losing FC. So I figured I'd backwash the filter and then take it apart to clean and remove any dead stuff that was in there that the backwash didn't...
  6. T

    New to TFP; No Free Chlorine;

    Based upon what I've read thus far, it appears that the 9+ years of using chlorine sticks has built up a residual of CYA in my pool that is not allowing me to get to a chlorine level that I can measure....other than zero. I've ordered a new test kit (TF-100) but is there anything that can be...