Search results

  1. J

    Jandy SWG PLC1400 Troubleshoot

    Hi Expert, I have a Jandy PLC1400 purchased in May 2023(1 year and 11month old). I found it recently stopped producing chlorine as I have it run at 100% overnight for 12 hours and no change in the FC level. I wanted to confirm if it is really the cell is bad or other things. Since my last...
  2. J

    Intelliflo pump is leaking at pump outlet

    @Rocket J Squirrel Hi Rocket, I noticed the same leak on my pump outlet. Just want to confirm that you remove the union and apply some tape to stop the leaking? Was there any oring failure? Thanks!
  3. J

    Dolphin S300i stops cleaning after a few minutes

    I have a S300i about 2.5 years old. It started to have the following issue recently. When starting a new cleaning cycle, it moves back and forth, then the impeller will start pushing water but only for about 15 seconds. The robot would keep moving for about 5 minutes with impeller not rotating...
  4. J

    Pentair Prowler 920 Stopped Working

    Hi Pool professionals, I have a Pentair Prowler 920 cleaner stopped working and I am trying to figure out which part is malfunction. Below are some observations Yesterday, the robot cleaner stopped working about 1 minutes after I turned it on and I was not able never turn it on after. The...
  5. J

    Help on Aqualink Troubleshoot

    Hi Experts, I have a Aqualink PDA PS8 that controls my pool pump and other equipment, and it was programmed to run every day from 8:30am to 7:00 pm. However, recently it seems have some issues and what observed made me very confused. Earlier this week, I noticed that my pool would started...
  6. J

    Do I have to consistently add Muriatic Acid to balance salt water pool PH level?

    Dear Experts, I have been maintain my 16000 gallon salt water pool myself and have a few questions below. 1. As the Chorine will be burn by the Sun and the Chlorinator is producing Sodium Hydroxide while generating Chorine, so the PH will always increase, hence I have to add Muriatic Acid...
  7. J

    Jandy SWG Service Light On

    Hi I am a new pool owner and first time saw this light on. The error code shows 120, based on the manual, it means low current in forward direction to Cell. So I need to take it off and clean it? What is the proper way to clean it? What is the cause of it? The PH value of my pool raise fast...
  8. J

    New Pool Owner Question about PH, TA and others

    After maintaining my pool a few weeks and had a couple of questions. Hope someone can help. 1. I lowered my PH from 8.2 to 7.6 about 10 days using MA but it increased to 8.2 again today. I am trying to understand why. First I guess it is because the TA is at 150 which is high. To lower the TA...
  9. J

    Very small bubble from pool return

    Hi Everyone, I am a new pool owner. My pool is about 4-5 years old. It is 16000 gal saltwater pool located in Texas. Basically I found the pool return feeds water to 5 nozzles, one placed at the bottom of the spa, and the other 4 placed around the main pool. Today I noticed very small bubble...
  10. J

    First time pool owner

    Hi Everyone, My name is Joshua. I just moved in to my new home I live in Austin Texas. It has a 16000 gal saltwater pool. I would like to start to learn how to properly maintain it. This place seems to be a great with a lot of people who is willing to help. I am glad I found here. I got...