Search results

  1. A

    Sheer Descent blockage

    I have two sheer descent waterfalls. Both operate from the same pump. There's is a T-junction that controls flow to each waterfall. One of the waterfalls is no longer spewing water. Even if I set the flow to the highest level and only to this waterfall, the water just trickles down against the...
  2. A

    How to replace Pentair FNS Plus Manifold

    Opened pool about a month ago and the water still have lots of small particles especially near return lines. I also see lots of sand (probably DE) on the floor. I decided to open the filter (never done this by myself before) and found that plastic on top of the grid has some cracks. I assume...
  3. A

    Replacing Pentair SAM Light

    Water leak caused damage on circuit board that holds receiver. The light still works, but no longer moves the color wheel. I already replaced the motor and it still doesn't work. It seems that the only option left is to replace the whole thing. The wiring is fully sealed with the unit itself...
  4. A

    Is my air pressure switch bad?

    My minimax heater doesn't ignite. Air blower fan keeps blowing forever and service light is on. I take off rubber tubing and blow some air directly into air switch, then I put tubing back and it works for day or two. Here is the picture of the switch. What does .65"VF means? I couldn't find...
  5. A

    Pentair Minimax NT STD transformer

    My pool heater is dead. No power. I think I blew transformer. I used multi-meter to check the power. According to pentair site, it is part number 472508. I found some pictures of this part on the net, but I'm concerned that the wires don't match exactly what I have. Is there a compatable...