    Combined Chlorine Craziness

    I'm at my wit's end here... I've been chasing a combined chlorine problem for about a month. 20,000 gallon pool.. water only just slightly cloudy looking down to the deep end DE Filter In-ground Vinyl liner FC 0.64 CC 5.31 TC 5.95 CYA 77 Ph 7.8 TA 110 CH 146 68 degrees I'm hesitant to shock...
  2. A

    Niche Grounding Headache

    Hey folks, I'm dealing with an electrical issue and could use some assistance. Background: My pool has a niche installed and previously had a light. The old owner drained the pool and stopped maintaining it. Part of this, for whatever reason, was to cut the power cable attached to the light...
  3. A

    DE Powder Dump Method

    Howdy, folks - I'm new to pool ownership and am humbled by the learning curve. I was on this site a lot last year and a bit this year as I open my pool myself for the first time. My pool starts are: In-ground 23000 gallons Hayward DE 4820 filter I added enough water to get the skimmer...