    Pentair MasterTemp 400 HLS intermittent error

    Yeah if that is the only next option (reading the Further Reading, that was all it suggested), then I'm going to call a service company. I saw a thread with pics about taking apart the heater manifold and not really something I want to get into, especially if that's still not the issue. Is it...
  2. N

    Pentair MasterTemp 400 HLS intermittent error

    I ordered a new regulator that came in today. I tested it and it did not open until 140 degrees. It also did not have a rating stamped on it. It is supposedly a pentair original part but a lot of people have complained that they aren't the correct part, so that wasn't a surprise. I took the...
  3. N

    Pentair MasterTemp 400 HLS intermittent error

    I may not have been clear. The regulator seemed to open fine. My hot water is only 110, so I had to boil some water to add to test it. At 125 it opened which could just be a thermometer discrepancy. At 130 it clearly was opened all the way. If you think I should have seen some movement before...
  4. N

    Pentair MasterTemp 400 HLS intermittent error

    I read through a bunch of posts including the massive "Further Reading" page about Pentair heaters and I'm still stuck. Our heater is plumbed for both our pool and in-ground spa, so we went to last night and I turned on the heater to get into the hot tub, and ran into an odd issue. The heater...
  5. N

    Thoughts on Diagnosing Mystery Leak

    Also, I just re-checked the pool skimmers. both of them seem to have hairline stress fractures, but they don't seem to be cracks all the way through and there's no give to the plastic, so not sure if these could be the cause. Can't say if I have ever noticed these, but the skimmer was...
  6. 20230905_181429.jpg

    20230905_181429.jpg

  7. 20230905_181237.jpg

    20230905_181237.jpg

  8. 20230905_180934.jpg

    20230905_180934.jpg

  9. N

    Thoughts on Diagnosing Mystery Leak

    Yes, there is a equalizing line between the pool and spa. When I shut off the spa schedule, I sealed that line to make sure the 2 didn't have any way to interact. The spa skimmer had cracked last year, so I used the pool epoxy/putty to seal it when I opened the pool. I assumed that was the...
  10. N

    Thoughts on Diagnosing Mystery Leak

    In-ground pool, in-ground spa. Same equipment, but the plumbing in and out for both are separate, so I can either run the pool or run the spa. I have it set to run 24/7 for the pool with a 30 minute cycle for the hot tub each evening. Symptom: Water level in both spa and hot tub drops quicker...
  11. N

    Additional troubleshooting help for my SWG

    Just an update...I watched it last night and caught it while it was back on, so it is cycling like it's supposed to. It doesn't seem to be 180 or 120 minute cycles, so not sure what it is. It's definitely not 60 minutes, so maybe 90 minute cycle. Just goes to show you can still learn something...
  12. N

    Additional troubleshooting help for my SWG

    Thanks, that helps. so it says the AquaRite is 180 minute cycle, and 120 minutes prior to firmware 1.55. I'm running v1.4, so if I read the post correctly, it is at 120 minutes. So at 25% it should run for 30 minutes, then stop for the other 90 minutes. if it's 180 minutes total, it should run...
  13. N

    Additional troubleshooting help for my SWG

    You're saying if it's at 100%, it's always generating, and if you have it on 50% it cycles on/off every ~30 minutes? I've never noticed that, but that would explain the behavior i'm seeing. The only reason I was alarmed at this behavior was because the last time it did this, it never cycled...
  14. N

    Additional troubleshooting help for my SWG

    Yep, that's the article i reviewed after I replaced the thermistor and still had issues. Also looked through past posts and couldn't find the same issue I'm seeing. I timed things...I can set it to "auto" and it will turn on and run and sometime between 20 and 30 minutes it shuts off. Still says...
  15. N

    Additional troubleshooting help for my SWG

    I have a Hayward Aquarite SWG with a T15 cell. The control board/cell were here when i bought the house in 2013. I replaced the cell last summer when it had issues. This past week we had some storms/power outages and my control board ran into the typical thermistor issues. When set to "Off" the...
  16. N

    Wiring new pump and SWG

    Yeah, looking around online it says if it's software version 1.5 or newer, it supports all cells, but only way i know how to check the software version is to have it powered on (and in use). Other threads on the forum ask the same question regarding upgrading software or whether you can swap...
  17. N

    Wiring new pump and SWG

    Yeah, neither my pool nor his has a breaker panel at the pool pad, only power lines that come out of the ground and into a junction box that then splits to the GFCI outlet/power switch for pool equipment and the light switch for the pool lights. I appreciate you sharing your breaker box there...
  18. N

    Wiring new pump and SWG

    The pump is the Pentair 3hp Intelliflo (EC-011028). The SWG he got is the Hayward aqr9 (for 25K gallons). His pool is ~19K gallons. The surge protector you linked is something that would be installed at the circuit breaker inside the house? I'm not sure I follow what you mean by "This will go...
  19. N

    Wiring new pump and SWG

    My brother bought a new home last year that has a pool and he's replacing his pool pump and installing a SWG this year with my help. He purchased the Intelliflo VS pump and the Hayward Aquarite SWG. He doesn't have a pool heater or anything else special, and he has a simple Intermatic T10X (not...
  20. N

    New Equipment installation questions

    Thanks for that info. I did not update the SWG to pentair, so it will (hopefully) be the only manual thing I have to control. But the Aquarite I have has the same flow sensors and will say if it has no flow. My old Jandy heater also had a flow sensor, so if the MasterTemp does as well, then I...
  21. N

    New Equipment installation questions

    The booster pump is to support the polaris vacuum we have. I wasn't aware those settings for the circuit would do anything, I just thought it was a label and set it as a cleaner. I've changed it back to "generic" to see if it continues to randomly come on. I've already begun asking about...
  22. N

    New Equipment installation questions

    I was taking pictures of the wiring and while i was there inspecting them, the booster pump kicked on again for no reason. Because the wiring is a bit messy, i'm going to lay it out in writing too so you can follow the picture. the top section behind the buttons was also a little messy and hard...
  23. 20200627_105727.jpg

    20200627_105727.jpg

  24. N

    New Equipment installation questions

    So I went to the gym this morning from 8am to 10am. When I got home, I just checked the app to make sure the booster pump hadn't started up again. Somehow the booster pump was on but the pool pump was off. I checked the 'history' section which showed that the pump shut off at ~8:25 this morning...
  25. 1593269273756.png

    1593269273756.png

  26. 1593269139444.png

    1593269139444.png

  27. N

    New Equipment installation questions

    Thanks, I played around with things some more to test out settings. I will install ScreenLogic on my computer so I can show you those pages you want. but that will probably be tomorrow. I also sent my pool guy an email asking about switching to the Intelliflo pump instead...we'll see what he...
  28. N

    New Equipment installation questions

    Yeah, it's partially my fault that the automated system isn't automated. We planned on just a few things and then he made some suggestions that sounded nice so we said yes, and I just assumed they'd work together since they're all Pentair. I just didn't do my research ahead of time and it is way...