Search results

  1. jklocke

    Floating deck, best sealer?

    If you can get it in your area, TWP 100 is the way to go. TWP® Total Wood Protectant Prepping the wood properly before applying any product is the most important step you can take.
  2. jklocke

    Intelliconnect support nonexistent

    I agree that there is little documentation on the Intelliconnect, although it does seem like Pentair is paying a little more attention to it than they used to. But like Allen said, it is automation meant for a simple pool. What pump do you have? Why is it connected to a relay and not through...
  3. jklocke

    WhisperFlo VS and intelliconnect

    Holy smokes! That's way too high to engage the flow switch. When was the last time you cleaned your sand filter? Maybe a deep clean would help, and it looks like Allen already mentioned that the IC40 should be installed with the flow up not down. I think redoing your plumbing will help a lot.
  4. jklocke

    WhisperFlo VS and intelliconnect

    If there is water moving through the system it is safe. What you don't want is the IC40 to be on when the pump is off. That could possibly lead to an explosion. What speed turns on the flow switch for the IC40? I doubt you will have effective skimming at speeds much lower than that. At...
  5. jklocke

    WhisperFlo VS and intelliconnect

    I can't check what is lit or not lit on my system because it's still put away for the winter. :sleep: If the flow light is lit then the IC40 is not generating chlorine. Why do you want to turn off the IC40? Let it make chlorine whenever you run the pump. Tweak the pump run time and the...
  6. jklocke

    WhisperFlo VS and intelliconnect

    I looked at the pics you posted on your thread, and it looks like the 2nd pump speed is set as a timer, not as a schedule. Check on that in the Pentair Home app and see if that makes it run correctly.
  7. jklocke

    Will superflo vs connect to intelliconnect

    Great to hear that it's working! Did you have to get them to update the firmware, or did the Intelliconnect ship with the updated firmware?
  8. jklocke

    WhisperFlo VS and intelliconnect

    That's great news! Glad you got everything working. My first thought is that you have to choose one or the other. But I think it would be worth seeing what happens if you run a line from the pool light junction box to a relay in the Intelliconnect, so commands can be sent from either the...
  9. jklocke

    WhisperFlo VS and intelliconnect

    M - Looking forward to hearing whether or not you can get the Whisperflo VST working with the Intelliconnect. They keep telling us it will work but we haven't seen actually happen yet. That's definitely an updated install manual for the Intelliconnect, so I'm hopeful for you! Let us know how...
  10. jklocke

    Will superflo vs connect to intelliconnect

    I am a part of a beta test group that Pentair is doing on updated firmware for the Intelliconnect. I reached out to my contact at Pentair this morning and this is his response: "342002 pumps made after 2020 are capable of connecting to our automation via RS-485, IntelliConnects with host...
  11. jklocke

    My Pentair Warrior SI stopped working!!!

    After you unscrew, lift the motor up and off of its connector and then reset it, then screw it back down.
  12. jklocke

    My Pentair Warrior SI stopped working!!!

    I've had a similar problem with my robot only running for a few minutes. Resetting the motor helped solve that for me. Here's Maytronics video about how to do that.
  13. jklocke

    Dolphin S200 starts/stops

    I had a similar problem with my robot - resetting the motor solved the problem for me. If that doesn't work, I would call about warranty coverage. Here's the Maytronics video on how to do that:
  14. jklocke

    Pentair Intelliconnect and MasterTemp 400 heater

    It is frustrating, and hopefully something they are working on fixing. It's hopeful to know they are working on updates to the Intelliconnect. Glad that they could update your firmware quickly and that it fixed your problem! Now that your equipment is all running right, be sure and read...
  15. jklocke

    Pentair Intelliconnect and MasterTemp 400 heater

    Does your pump say it's connected to automation? I'm assuming you were able to control the pump from the app before the Intelliconnect was added to the mix. Which model pump do you have - 011075 or 011076? Have you contacted Pentair support? Maybe your Intelliconnect needs a firmware update...
  16. jklocke

    Pentair Intelliconnect and MasterTemp 400 heater

    Yes, the pump needs to be controlled through the Intelliconnect in the Pentair app. This is to keep the heater from being turned on if the pump isn't running and to shut the heater off if the pump gets shut off. All of your devices need to be added under the Intelliconnect You will probably...
  17. IMG_0142.PNG

    IMG_0142.PNG

  18. jklocke

    Pentair Intelliconnect and MasterTemp 400 heater

    Sublime - Welcome to TFP! Pictures of how things are wired in the Intelliconnect would be helpful. It sounds like it's wired correctly (after you disconnected it from the relay) if the heater turns on when you hold down both relay buttons in service mode, but let's be sure. Thoughts - do...
  19. jklocke

    Intelliconnect needs jumpers for IN load on relays?

    I'm not sure if that error is from the missing temp sensor or a problem with the iChlor30. I would wait until you also have the water temp sensor running before we can determine if the iChlor30 has a bad sensor. How are you testing for salt? You need to get a Taylor K-1766 salt test kit to...
  20. jklocke

    Intelliconnect needs jumpers for IN load on relays?

    Did you test for salt before adding the 4 bags of salt? Every time you add liquid chlorine to the pool you add salt too, so I'm guessing you already had a significant amount of salt in the water already. Did your regular additions of chlorine increase your FC by the expected amount? Your...
  21. jklocke

    Intelliconnect needs jumpers for IN load on relays?

    PB - There is no ground in the Intelliconnect. I'm not an electrician but I'm going to guess it's ok and that it has something to do with the CB being grounded in the breaker box. There is a bonding lug on the SWG power center, and you should connect that to your bonding wire. Glad you're up...
  22. jklocke

    Intelliconnect needs jumpers for IN load on relays?

    Glad I can add some knowledge to this great forum that I continue to learn so much from! I don't know why they "modified" the RS-485 ports, other than to simplify the connections for people so they didn't have to stack multiple wires. It seems like it would have been better to name one Pump...
  23. jklocke

    Intelliconnect needs jumpers for IN load on relays?

    As Jim and Allen said, your RS485 cable from both your pump and Intellichlor only needs 2 wires - green and yellow. They can be connected separately (1 & 2, 3 & 4) or all the green on one (1 or 3) and all the yellow on one (2 or 4). I used all 4 ports on my setup because like you I only have...
  24. intelliconnect rs485.jpg

    intelliconnect rs485.jpg

  25. jklocke

    Intelliconnect needs jumpers for IN load on relays?

    PB - You've probably already figured out this, but I thought I'd throw this out just in case you haven't. You are correct that both your pump and Intellichlor power center should be hardwired directly to their breakers and not through the Intelliconnect. They only need RS-485 connections to...
  26. jklocke

    Pentair Home down? UPDATE: reinstalled app, back to normal...

    I just checked mine remotely and it seems to be working for me. Maybe local internet issues?
  27. jklocke

    Intelliflo communication error - I can't increase chlorine output manually or through the app

    With the Intelliconnect, to manually change your pump speed or output settings on your iChlor, you need to put the Intelliconnect in Service Mode. Open up the box, push the button marked "MODE" once to switch from Auto to Service, and you should be able to make adjustments. When you are done...
  28. jklocke

    I’m totally confused. Cloudy water and too much vocabulary

    I'm familiar with the area around Moline, I went to Augustana and my grandparents had a farm near Lyndon IL. Where exactly are you? I'm glad to help find some stores closer to you that have muriatic acid and liquid chlorine. Menards usually has some of both at pretty good prices.
  29. jklocke

    Need to replace 15 year old s/s pump -- looking for feedback

    Have you looked into the newer Intelliflo3 pumps? The Intelliflo3 with I/O board (model 011076) has the ability to control 2 devices (including an SWG) using the Pentair Home app, so you wouldn't need to also buy an EasyTouch or other automation system. I would recommend an IC40 with Power...
  30. jklocke

    Add My IC40 to IntelliConnect

    On my Pentair Home app, the IC40 is listed as a sanitzer under the Intelliconnect device. Is that an option for you? On a side note, how did you get Pentair to push new firmware? I never get anywhere with them about firmware updates!