New VS Pump - help with timers please

larrybbaker

Active member
Apr 21, 2020
28
South Central PA
Pool Size
20000
Surface
Vinyl
I upgraded to a Hayward W3SP2603VSP pump and am having a hard time figuring out the settings to have it run at a set speed until I manually change it. Pump is stand alone, no automation. The way I read the manual if I set the start and end time as the same the pump would just continue running and not shut off. Last night it shut off with the timer set 12a-12a. What am I missing? Anyone share their settings?
 
Set it to 12a to 11:59p
Or set overlapping timers:
 
  • Like
Reactions: larrybbaker
With Jandy they recommend setting a 5 minute break between stop and restart. Works great for me and I did have issues when it was the same stop/start time. There is no way to continuously run that I have found.

Also Jandy has a default or "Pool" speed where it automatically goes to when first turned on. Mine is set for 1500 RPMs.
 
  • Like
Reactions: larrybbaker