- Jul 15, 2024
- 29
- Pool Size
- 17500
- Surface
- Fiberglass
- Chlorine
- Salt Water Generator
- SWG Type
- Hayward Aqua Rite (T-15)
We just got a Water Guru*.
Water Guru is in our skimmer and Water Gura has been giving me Low Flow Warnings.
Pump is Heyward TriStar 900
Here is my Observaed Data:
250W At 1850 RPM, Filter 0 PSI, Water Guru Flow 14GPM
460W At 2300 RPM, Filter 2 PSI, Water Guru 17GPM
855W At 2875 RPM, Filter 8 PSI, Water Guru 19GPM
Does Water Guru suck at measuring flow or do I have a potential plumbing issue? Pool and equipment are all new as of last year.
*I understand they are not super accurate for measuring pool chemistry but we are away for up to a week at a time in the early and late season so I just wanted something that will give me a good sense if my FC is drifting way too high or way too low while I am away.
Water Guru is in our skimmer and Water Gura has been giving me Low Flow Warnings.
Pump is Heyward TriStar 900
Here is my Observaed Data:
250W At 1850 RPM, Filter 0 PSI, Water Guru Flow 14GPM
460W At 2300 RPM, Filter 2 PSI, Water Guru 17GPM
855W At 2875 RPM, Filter 8 PSI, Water Guru 19GPM
Does Water Guru suck at measuring flow or do I have a potential plumbing issue? Pool and equipment are all new as of last year.