SWG install rerouting pipe to make room

jlim0930hh

Active member
Jan 5, 2020
25
Dallas,tx
I am thinking about installing the jandy PLC1400 and reading the manual it looks like I need a clearance of about 17 inches but I do not. What would be the best way to reroute the pipes to have enough space?

I was thinking about changing the direction of the elbow from the heater from up to the wall and add two more elbows to lengthen it and add the backup valve and the swg and remove the chorlinator?
 

Attachments

  • IMG_7745.jpeg
    IMG_7745.jpeg
    80 KB · Views: 7
  • IMG_7746.jpeg
    IMG_7746.jpeg
    72 KB · Views: 7
I was thinking about changing the direction of the elbow from the heater from up to the wall and add two more elbows to lengthen it and add the backup valve and the swg and remove the chorlinator?
That will work. You do not need a check valve with a SWCG because it only produces chlorine with flow.

You could also install a vertical U and put the SWCG on the downward flow side. See picture B or C
IMG_8003.jpeg
 