- Aug 11, 2012
- 175
- Pool Size
- 9000
- Surface
- Plaster
- Chlorine
- Liquid Chlorine
Hi all. My 2hp single stage pentair pump died so I replaced it with a Leslie’s Jacuzzi JVS270S variable speed pump (max 2.7hp). Since this pump sits higher I had to move the pump location due to overhead piping from the filter. I got it all back together and it appears I have a suction leak beacuase the pump basket will not completely fill. I’ve greased up all o-rings, went back and externally double cemented the pipe fitting joints. I’ve also replaced all the Jandy valve o-rings and greased them and even wrapped all connections with cling wrap to send I can choke off any suction leaks. Any ideas on what I may be missing, other that an underground leak :/
Here is a link to my setup I inherited when we bought the house. The pics are before and after.
Here is a link to my setup I inherited when we bought the house. The pics are before and after.
Attachments
Last edited: