iChlor 30 Effectiveness

elmoco

Gold Supporter
LifeTime Supporter
Aug 22, 2011
68
El Paso, TX
Pool Size
16000
Surface
Plaster
Chlorine
Salt Water Generator
SWG Type
Pentair iChlor 30
hi. i'm beginning to doubt the chlorine production of my ichlor 30. so i'm running a test using my hot tub (400gals). according to the Pool Math calculator, if i run the SWG for 1 hour at 100%, the FC should raise by 12. if it only raised by 3 (25% effective), does this mean it's going bad? thanks all
 
hi. i'm beginning to doubt the chlorine production of my ichlor 30. so i'm running a test using my hot tub (400gals). according to the Pool Math calculator, if i run the SWG for 1 hour at 100%, the FC should raise by 12. if it only raised by 3 (25% effective), does this mean it's going bad? thanks all
Typically a cell is working or it's not - no in between.

It might be wise to assume 80% of mfgr claim of FC production however, as typically they're very optimistic.
 
  • Like
Reactions: elmoco
This at least gives me some hope that the cell is functional. i'll keep monitoring
Hey Elmoco !!

Have you passed an Overnight Chlorine Loss Test ?
More often than not, hidden organics is chewing through the FC as quick as its produced.
that's in process. i'm trying to run a controlled OCLT, but the family and doggie keeps "sabotaging" it :)
 
  • Like
Reactions: Newdude
Typically a cell is working or it's not - no in between.

It might be wise to assume 80% of mfgr claim of FC production however, as typically they're very optimistic.
at least this gives me hope cell is still ok. i'll keep monitoring when i complete OCLT. thanks
 
Thread Status
Hello , This thread has been inactive for over 60 days. New postings here are unlikely to be seen or responded to by other members. For better visibility, consider Starting A New Thread.