From Tablets to SWG - No Chlorine After 48 Hours

Aviry

New member
Jun 19, 2022
2
Israel
Hi Guys, new here.
living in Israel and have an in ground pool with a cover on most of the week.

For the last 2 years I've been using Chlorine tablets and just before the weekend I've shifted to SWG.

The guidance I got from my pool guy is to see the SWG to 100% for a day or so and then lower it once I'll get to the right chlorine levels.

Long story short - 48 hours have passed with the pump and SWG running straight, water is crystal clear, PH is fine like it was before. but there is no FC.

The SWG company (Magen Ecoenergy A global manufactuer of solar heating solutions) said that if the water were fresh this wouldn't happen, not an expert so I'm not sure how the fact that I used tablets before (and managed to get my FC levels up) is connected.

Help?
WhatsApp Image 2022-06-19 at 6.49.43 PM.jpeg
 
A,

Tell us which model of SWCG you have.

How big is the pool and how much salt did you add?

Does the cell have a read out showing the salt level?

Is the power center giving you any errors?

Pics of the cell and power center would be great!!

Thanks,

Jim R.
 
Thanks for the quick reply.
Yes the SWG shows there is enough actually. no errors, everything works as it should.

since taking this photo the salt level event went one up, so full but not too full.IMG_7425.jpg
 
Thread Status