Low flow in Spa mode, with Pentair Mastertemp heater

Jan 27, 2014
1
Having a flow issue My master temp 400 and I’m not sure if it’s the bypass. When I run it in spa mode 3250 rpms the flow is much weaker than Normal. It still heats but it’s about 50% less water flow than usual. Mabe 1 out of 5 times turning it on it will flow Normal so I’m thinking it’s the bypass?
 
Welcome to TFP.

Show us pics of your equipment pad.

Which bypass are you thinking of?

All the water flow must be going someplace. If not to the spa then where?
 
Mabe 1 out of 5 times turning it on it will flow Normal so I’m thinking it’s the bypass?
Have you monitored the pressure in the filter when it flows "normal" (1 out of 5x) vs when you think the bypass is causing an issue? Higher speed should increase the pressure but is it consistent each time you put in Spa Mode?

Are you positive your automated valve on the return side is fully open to the spa and closed to the pool? Could it be getting stuck or leaking?
 