To me those are not enough air bubbles to worry about. Perfection is not the goal.
Does your sand filter have an MPV? Do you have a RECIRCULATE setting on the MPV? If so try running your pool on RECIRCULATE and see what the flow out of your returns is.
Do you have a heater bypass valve? Heater Bypass - Further Reading
See if your filter or heater is restricting your return flow.
Understand that lower filter PSI is better. Higher PSI indicates more restrictions in your plumbing.
If you have good flow with your heater bypassed then I would examine your heater coil for scale.
Post pics of your equipment pad, pluming and valves.
Understood on PSI. Before the replumb, I was running at around 15, so if anything the new setup should be slightly better.OK it’s getting dark now but I’ll post some pics tomorrow. Thank you.
There are two safety systems; the timer is one and the flow switch is the other.One question about the flow switch. If it does get stuck in a flow position, what are the implications if the SWG is on the same timer as the pump?
Super helpful thank you. I can see in diagnostics if the switch is showing flow or no flow so will definitely keep an eye out. I removed it earlier today to examine and everything appears in working order.There are two safety systems; the timer is one and the flow switch is the other.
Since you have two, it will probably be ok, but be alert to flow switch problems.
Maybe remove it periodically for inspection and replace it if the spring seems weak.