Was working last year but notice the service light active when turned on but cleared after running a while. Eventually replaced thermister and worked until end of pool season. Tried system in April and control board turns on and gives me R3 and then goes dark. Blower motor does not turn on. No LEDs active on back of control board. No LED on ignition module. Check thermister and found it cracked. Replaced and still nothing. When I turn on the 120v breaker I see the ignition module light up a few seconds and turn off. No flashing. Replaced Control Board ($$)no change. Bypassed the F1 F2 on ignition module and connected to give power directly to blower motor and it powers on so it works. But no heat. Replaced ignition module ($$) and back to square one. Don't know what else to replace. When I press the yellow button on the back of control board the display flashes 104. Could igniter go bad? Gas is on.