Recent content by Wfoskey

  1. Wfoskey

    Help! I screwed up and wired motor wrong

    yes it did. All good now. Thanks to everyone. You guys are awesome!
  2. Wfoskey

    Help! I screwed up and wired motor wrong

    Checked continuity, OL on left side, 0.1 on right
  3. image.jpg

    image.jpg

  4. Wfoskey

    Help! I screwed up and wired motor wrong

    swapped relay back to original. Pump won’t run. Checked voltage across relay. 0 when switched off. 23 volts switched on.
  5. Wfoskey

    Help! I screwed up and wired motor wrong

    You guys have been great. I hate to admit what I found. I couldn’t see the plug below. Both wires were plugged to the same terminal. Pump is running now, but won’t stop with the switch. It turns on when the breaker is turned on.
  6. IMG_2317.jpeg

    IMG_2317.jpeg

  7. Wfoskey

    Help! I screwed up and wired motor wrong

    Got around 120 on each wire to ground. Hooked it all back up. Tripped breaker again.
  8. Wfoskey

    Help! I screwed up and wired motor wrong

    Changed relay and rechecked the voyage on the 2 red wires. Voltage read 240
  9. IMG_2314.jpeg

    IMG_2314.jpeg

  10. IMG_2315.jpeg

    IMG_2315.jpeg

  11. image.jpg

    image.jpg

  12. Wfoskey

    Help! I screwed up and wired motor wrong

    continuity is good on leads and ground. Voltage reading 43.5 volts.
  13. IMG_2307.jpeg

    IMG_2307.jpeg