Recent content by vdubin71

  1. V

    Heat pump for 18' round AGP?

    Anyone have an 18' Round AGP in the North East using a heat pump heater? Would love to hear what heat pump you have and your experience. Thank you.
  2. V

    Heat pump for 18' round AGP?

    Thanks again Rich! Yeah, been weeding through reviews and it seems service is hard to come by for the TTI Fab units.
  3. V

    Heat pump for 18' round AGP?

    Thanks Rich, that is helpful. So it looking like I am kind of at the tipping point with the 65k Raypak. Whats everyone's thoughts on the TTI Fab Stratos units? They have 80k and 100k units. The Website for them is not impressive but they have a a decent warranty, 5yr parts/2yr labor and made...
  4. V

    Heat pump for 18' round AGP?

    Thanks copterdoc! I do have the ability to get 220 to the pool, just pull another circuit through the existing pipe/run, no issue there.
  5. V

    Heat pump for 18' round AGP?

    Hi Everyone. The family is complaining that our pool was cold last summer and convincing me that we should get a heat pump for our 18' round AGP. Our summer was a bit cooler than normal and windy last year. Having a bit of an extended season is also a plus for us. I don't have a way to get...
  6. V

    Need wiring help - Problems with new 2 Speed Motor

    Yes, that is exactly what it was. It was popped out of one of the pivot points and stuck. Popped it back in and it runs in low speed now. Thanks again!
  7. V

    Need wiring help - Problems with new 2 Speed Motor

    Thanks Allen. Yeah, I'll blame that on being color blind :) The other issue was weird but fixed it per the above. Thanks for your help. 2 speeds here I come!
  8. V

    Need wiring help - Problems with new 2 Speed Motor

    Hi Everyone, I solved the problem. 1. wires crossed from the switch re: Lo speed wire going to the high speed terminal and Hi speed wire going to the low speed terminal. Switched them and all is good. 2. To resolve the low speed only working for a short time issue: I saw from on YouTube that...
  9. V

    Need wiring help - Problems with new 2 Speed Motor

    Hi Everyone, I just replaced the motor on my pump with a 1HP 2 Speed BN37V1 motor. I have the correct switch/end cover assembly and wired everything up this weekend. With lots of excitement looking forward to the benefits of 2 speeds, I turned it on to "Lo" on the switch but its definitely in...
  10. Pump_dia.jpg

    Pump_dia.jpg

  11. Pump_cover.jpg

    Pump_cover.jpg

  12. Pump_wires.jpg

    Pump_wires.jpg

  13. V

    Upgrading AGP to SWG, new pump and PVC lines - ???

    Thanks for the input and motivation!
  14. V

    Upgrading AGP to SWG, new pump and PVC lines - ???

    Thanks for the tip Maddie! I will order the kit as soon as I place the order for the SWG...I didn't pull the trigger on that yet. Hi Kelly, yes I am keeping the DE Filter. I have been having a problem finding a 1HP 2 speed pump like the Pentair Opti-Flo (though I find lots of them from brands...
  15. V

    Upgrading AGP to SWG, new pump and PVC lines - ???

    Hey Newdude! Thanks for the guidance and encouragement. I can't wait to join the Dark side! ...I will be there soon...