Recent content by twoschims

  1. T

    Aqua Logic / Hayward GLX-PCB-MAIN: Self-Setting Itself Into Service Mode

    I had same issue. I changed the battery pack in the remote and it fixed the issue. The exact battery pack was hard to find but Batteries Plus made me a new battery pack.
  2. T

    Aqua logic goes into service mode on its own.

    Model # AQL-PS8 Serial # 5L0602-1013322 After shading the control panel for several days, the problem seems to be rectified. The pump ran all night and all day yesterday with no issues. I can only assume being exposed to 118 degree temp was a factor.
  3. 20210621_095122 (1).jpg

    20210621_095122 (1).jpg

  4. T

    Aqua logic goes into service mode on its own.

    Control board is 15 years old, but was overhauled 3 years ago by B and L Enterprises in Tuttle, OK. Aqua Logic GLX PCB MAIN System Board #263139243763
  5. T

    Aqua logic goes into service mode on its own.

    The aqua logic control panel was in direct sunlight, but is now shaded. It ran overnight but at some point,, it went into service mode on its own again. I took it out of service mode, and it started up again, but not confident it won't go back into service mode later as the temperature gets...
  6. T

    Aqua logic goes into service mode on its own.

    Would extreme outside temperatures, if. 115 degree days cause it to automatically go into service mode. I have Pentair variable speed pool pump.