Recent content by TODD2112

  1. T

    PLC1400 Strange behavior

    2 weeks ago I cleaned my SWG there was scaling and build up. Re-installed. Checked chemistry NO FC... I retested my pool today 5-11 for FC. None to be had. Reset Aqua Pure 1400, or should I say I turned off all power to controls. FLOW light is on CELL RESTING light comes on No Error Codes...
  2. T

    Jandy Aquapure 1400 (rectangular style) 120 and 121 codes

    Re: Jandy Aquapure 1400 (rectangular style) 120 and 121 code Hello and thanks to all for the input. Just installed new 3 port Jandy 1400 cell. The plumbing was easy but a bit tight with exisiting configuration, good thing I have a bit of mechanical appitude, spatial relations, and know how to...
  3. T

    Jandy Aquapure 1400 (rectangular style) 120 and 121 codes

    Re: Jandy Aquapure 1400 (rectangular style) 120 and 121 code I have decided to invest and change out older cell. Cell, DC cord etc.. Thanks for the information
  4. T

    Jandy Aquapure 1400 (rectangular style) 120 and 121 codes

    I have an Aquapure 1400. 6 yrs old. Receiving 120 and 121 codes for past 3 weeks. I have cleaned the generator there was scale at ends of plates and was removed due to cleaning. (water muratic acid mix) The internals of the Generator are free of scale and on the surface appear to in...