Recent content by Thegatorvault

  1. T

    Zodiac Jandy JXI400N Problem

    Thanks for the reply..... Low flow rate was the other 'root cause' Jandy listed in the manual. I don't believe this is applicable to me since my water features and return flow appear normal. Answers to your questions: 1. Last DE filter backwash was done in August. Generally speaking...
  2. T

    Zodiac Jandy JXI400N Problem

    Hey gang..... Well, I have had my heater for about 2-1/2 years and has been working flawlessly. Last weekend, used it for the first time this season for the kids, and noticed it was making a noise every so often. Sounded like it was shuttering/shaking a bit and then it would go away. This...
  3. T

    2018 Jandy Aquapure - 'No Flow' Issue

    The system has been working pretty consistently and properly since the last post (pretty much but see below). Bob at BP Electronics did call me back a week ago on Friday. Unfortunately he was involved in the design of the original Aquapure boards/interface but at some point when the total...
  4. T

    IAqualink 2.0 acting up

    Got it. I'm on an iphone so I don't have this screen. RE 'no flow', it was not a hardware issue. Builder installed a brand new sensor (thinking it was a bad sensor) and problem persisted. Only went away after app/schedule deletion and breaker resets. Still not sure what the root cause was...
  5. T

    IAqualink 2.0 acting up

    Not to get to far off topic but curious about your comment.....when you say “clear out all APP data”, are you talking about going to the WEB link in the app, going to ‘System Settings’ and then hitting ‘Clear Memory’? What does this do? If my ‘no flow’ glitch happens again, I may go this...
  6. T

    IAqualink 2.0 acting up

    Good to know. I didn’t even think about the computer but if anything acts up again related to the app, I will go that route as a way to troubleshoot. As I said, my app works 100% correctly all the time at this point. I hardly ever use the handheld now.
  7. T

    IAqualink 2.0 acting up

    Yeah my problem was related to the 'my systems' page on the app; my pool was listed but had the red dot (instead of green), so I could not actually get in to any of the function. Apparently there was 0 communication between the panel and the wifi and again would guess it was the tp-link (not...
  8. T

    IAqualink 2.0 acting up

    I had this problem several months ago. I have an Aqualink2.0, the 18 channel RF Transceiver, and a tp-link at the panel for wifi-boost communications (along with a plug in wifi-booster in the house at the router). Connection went away and my pool showed the red dot in the phone app; I could...
  9. T

    2018 Jandy Aquapure - 'No Flow' Issue

    Well, I got it working correctly, but to be honest, not sure exactly how. Finally got my builder's tech on the phone Wed of last week. The tech thought maybe the schedule was causing an issue (not really sure how) so he had me use my phone app to delete my schedule and create a new one. I set...
  10. T

    2018 Jandy Aquapure - 'No Flow' Issue

    Well, despite a brand new sensor/cable, the issue has cropped up again. Basically if the system starts in auto, the 'no flow' condition occurs. When I stop and restart manually, it works fine for the rest of the day. I think this is either a board issue or something in the logic. My builder...
  11. T

    Near Final Design on New Build - Feedback Please

    Yes I have all Jandy equipment and have been happy with the performance, automation, and interface. I have the iAquaLink app on my phone and can control everything from either my phone or the remote that came with the system. I use my phone most of the time. After almost a year and a half, I...
  12. T

    2018 Jandy Aquapure - 'No Flow' Issue

    Hey guys....... So this post stems from another post I had when my FC levels would not stay level and kept dropping about a month or so ago. When I originally noticed my FC levels off, I started checking things and noticed my SWG was showing 'no flow' so it was not making chlorine. I called my...
  13. T

    FC dropping

    Ok....might have figured out what is going on. I realized while resetting my Jandy SWG % that I have the dreaded 'No Flow' error. I have plenty of flow and I know the sensor is clean since I got this error around the time I was trying to figure out what was going on; my builder told me to...
  14. T

    FC dropping

    Small update......my FC level has been slowly coming down. I did a full log two days ago....results: FC - 7.5ppm pH - 7.5 TA - 70 CH - 275 CYA - 60-70 Salt - 3800 Temp - 91 CIS - -0.39 My SWG has been at 80% and running for 11hrs per day since I finished my SLAM. I purchased 8lbs of calcium...
  15. overflow pipe 4.jpg

    overflow pipe 4.jpg