Recent content by slickrick2002

  1. S

    High flue gas post hurricane.

    Update: replaced main circuit board and heater is back working. Did have to go into the main menu and switch to remote control but appears all is back to normal. Got a board on eBay $100.
  2. S

    High flue gas post hurricane.

    Checked ohms vs neighbors..same heater. Same readings
  3. S

    High flue gas post hurricane.

    jxi gen2. I want to ensure I have jumped the sensor correctly to rule it out. Idk how to test the sensor that’s why I put a wire in there to try and jump it. I put a jumper wire from one side to the other and removed the two white wires from the sensor. Does not clear. I’m thinking it’s the...
  4. S

    High flue gas post hurricane.

    It’s a jandy heater 4-5 years old.
  5. S

    High flue gas post hurricane.

    So post hurricane I’m getting a high flue gas temp alarm so no heater. I think I have it bypassed with a wire but alarm will not clear. I just used a jumper wire but idk if anything else is needed to rule out the Ti.
  6. S

    CH/PH rise

    All the numbers are pretty steady... new numbers: FC/TC 5ppm PH 8.0 Alk 70 Hardness 350 Cya 60 Salt 3200 Borate 50ppm For me to maintain 7.4-7.8ph I have to use 1/2 gal of acid per week or more. Which to me is to much for only 16500 gals.
  7. S

    CH/PH rise

    Ph is high and alk is 90. Can’t read ph over 8 but it’s up there
  8. S

    CH/PH rise

    Ta and ch appear to be fine but it’s still early. Ph rise is crazy. Calcium noodles starting to come back slowly
  9. S

    CH/PH rise

    Looks lik ph rise is still around .1-.2/day with borates at 50ppm. Does it ever stop? Im rising .1-.2ppm/day. Chlorinator at 40% all water features off. I was told this will get better over time but it hasn’t. These calcium noodles are not joke either. Tired of fooling with it. There has to be...
  10. S

    CH/PH rise

    Confirmed ph rise today. Last add was Wednesday was 7.4 and Friday 7.8. Will not add acid for a couple more days just to see but I can’t measure above 8.0. ChH still 325
  11. S

    CH/PH rise

    new numbers: FC/TC 3ppm PH 7.8 Alk 80 Hardness 325 Cya 60 Salt 3300 Borate 50ppm Drained half the pool got hardness down to 325. PH rise is still and has always been excessive. Im trying to target 7.6 but in order to do so will have to add acid every 3 days. I get it to 7.4 but its back at...
  12. S

    CH/PH rise

    FC/TC 2ppm PH 7.9 Alk 80 Hardness 375 Cya 20 Salt 2700 Still a little high on hardness so will drain more and refill. I dont see this hardness issue going away. Fill water was 100ppm. Want water as close to perfect as i can before I add borates.
  13. S

    CH/PH rise

    Last I checked was around 150 when I filled it. Have not refilled to much this year. I try to catch rain water by raising the level on my auto drain. All water features stay off as well except maybe one day on the weekend. I will check fill water again today.