Recent content by Scowman

  1. S

    Aquapure Board Test Reading Slightly Off

    What brand of dielectric grease do you use?
  2. S

    Aquapure Board Test Reading Slightly Off

    I think dielectric at the base under the o-rings and retainer plate is a good idea but definitely not a good idea on the pin to socket connection. If anything that should be conductive grease. I often find people think dielectric grease is for electrical connections when it really is for...
  3. S

    Aquapure Board Test Reading Slightly Off

    Is the arcing between wire socket and pin? If socket and pin arcing is the problem would you not want conductive grease? I though dielectric grease is NOT conductive. Would you not want something like carbon conductive grease between pin and socket? If pin to pin arching is the problem then I...
  4. 1715697567648.png

    1715697567648.png

  5. S

    Aquapure Board Test Reading Slightly Off

    Found the problem. Center electrode corroded. This is the second cell that did that in less than 1 Year service life! What am I doing wrong here? Is Aquapure just junk?
  6. IMG_1833[1].JPG

    IMG_1833[1].JPG

  7. S

    Aquapure Board Test Reading Slightly Off

    Combined chlorine is barely above zero. If a full day's worth of 100% production is consumed, wouldn't cc go up?
  8. S

    Aquapure Board Test Reading Slightly Off

    I ran this cell voltage test I I get somewhere between 13 and 17vdc which is way below spec. Is that a board problem or a cell problem? How can I tell?
  9. 1715692785087.png

    1715692785087.png

  10. S

    Aquapure Board Test Reading Slightly Off

    So I ran these three again (my original tests). The temps came back one degree low and this confirms they are within spec. The salt came in at 2.6 but I did recalibrate it. Not sure how to uncalibrate it now. Gotta go to work... More tomorrow.
  11. 1715612801805.png

    1715612801805.png

  12. 1715612984457.png

    1715612984457.png

  13. S

    Aquapure Board Test Reading Slightly Off

    These are 11.85v and 5v so they are good.
  14. 1715612068699.png

    1715612068699.png

  15. S

    Aquapure Board Test Reading Slightly Off

    This test is 20v so that is good.