Recent content by sc_boat

  1. S

    Pool Pilot Check Clean Cell

    My reading on system is 4000ppm, I have a salt tester and it reads around 3200ppm. Would that cause the check / clean cell error. If so, I can recalibrate the system to correct salt ppm.
  2. S

    Pool Pilot Check Clean Cell

    Ordered and installed new cell. Still check/clean cell and when run the system check it still has low amps. Should I replace cord next?
  3. S

    Pool Pilot Check Clean Cell

    I inspected and no white crusties. I did notice what looked like corrosion on some of the inner plates and did the acid cleaning. Helped a little but did not eliminated completely. Had some bubbling going on during acid cleaning. I am guessing the Volt/Amp out of an acceptable range is what...
  4. S

    Pool Pilot Check Clean Cell

    I have a Pool Pilot Digital and the Check Clean Cell begins flashing periodically. When this happens the volts and amps drop to around 16/4. When it is not flashing they are around 20/6. Power level is on 2. It is still producing chlorine but I am running it much more than use to. Any ideas...