    New OB RPi Set Up

    I don’t understand why you are having issues. You should probably post on the repo where folks that have the same equipment as you can help. Anyhow there are two command sets for the Superflo just like there is for IntelliFlo and yes the commands are the same. You must constantly send the...
  2. R

    New OB RPi Set Up

    Based on your screenshot above, it looks like you do not have the input configured to 10k thermistor. Click on the gears and change it. This should be displaying in KOhms.
  3. R

    Raspberry Pi Thermistor

    Here are some links that describe how to set this up. https://github.com/rstrouse/relayEquipmentManager/wiki/Temperature-Sensors And here is one integrated into a full blown Nixie controller for your pool...
  4. R

    Pentair IntelliCenter Pool Control Dashboard Instructional Guide

    The default port number is 5150
  5. R

    New OB RPi Set Up

    Don't forget if you are running PM2 and have cached the startup you will need to shut down the pm2 instance `pm2 stop REM` then run `npm start` from the relayEquipmentManager directory to rebuild the cache the first time.
  6. R

    New OB RPi Set Up

    I responded to the issue in the repo. You should pull the updates from the repo as I believe that it is still trying to digest the invalid value. I added some checks to read sensor value out of the pin data.
  7. R

    New OB RPi Set Up

    This is a feed on the Mega BAS that feeds the generic value. Select the I2c #1 tab at the top then select your Mega BAS card from the device list. You will find the Feeds listed on the device.
  8. R

    New OB RPi Set Up

    I responded to your issue in the repo. You need to make an adjustment to the feed from the MEGA-BAS.
  9. R

    New OB RPi Set Up

    Here is the link on how to set up a temperature probe. https://github.com/rstrouse/relayEquipmentManager/wiki/Generic-Devices#setup
  10. R

    New OB RPi Set Up

    To set up the temp probe create a generic temperature probe. The instructions on how to set this up can be found here. Sequent Microsystems Boards
  11. R

    Weird error with Nodejs-poolcontroller "Error triggering nixie schedules"

    Nixie is the underlying pool controller that can either operate as a standalone pool controller or a companion to an existing panel. In this instance the message you are receiving is because nixie cannot calculate a start and or end time for one of your schedules. Most often this is due to...
  12. R

    Pentair IntelliCenter Pool Control Dashboard Instructional Guide

    If you have not updated dashPanel and have updated chrome. It will pop up block the the overlays. Update dashPanel.
  13. R

    16 July 2024 Finishing Up my OB Pool

    Yes njsPC supports RS485 on MasterTemp, UltraTemp, and UltraTemp Hybrid heaters.
  14. R

    IntelliValve Upgrade Update

    Hmmm... field programmable so they are programming through the data cable. Interesting.
  15. R

    Two IntelliChlor Cells with one IntelliCenter?

    It may be looking at the wrong chlorinator in REM for the spa. Open an issue or discussion in GitHub and attach a replay.