Recent content by RJS3

  1. RJS3

    Pentair Pool Heater makes a loud bang (backfire?) when it ignites.

    Thanks @ajw22 Wondering if @ps0303 has a thought on this. He helped someone earlier in July with a gas flow issue.
  2. RJS3

    Pentair Pool Heater makes a loud bang (backfire?) when it ignites.

    @ajw22 @swamprat69 @1poolman1 So I have an update on this heater. I had a wedding in July and life got in the way of taking some next steps on this problem. But I borrowed a manometer and hooked it up to the valve today. I turned on the gas and found that the static pressure (the pressure...
  3. IMG_5660.JPG

    IMG_5660.JPG

  4. RJS3

    Pentair Pool Heater makes a loud bang (backfire?) when it ignites.

    Thanks @Pdxonthego1. I’ve had to put this on hold for a bit as my son just got married, but I’ll be tearing into this shortly. Not sure how the 206a compares to the pentair or if there is a similar “sping in the heater core of the bypass line” but it’s with checking out. I’m also wondering if...
  5. RJS3

    Pentair Pool Heater makes a loud bang (backfire?) when it ignites.

    What’s the best way to access the burner
  6. RJS3

    Pentair Pool Heater makes a loud bang (backfire?) when it ignites.

    @ajw22, I hear you on the job. I did clean up the grounds, and the electrical tape was some added sheathing when a mouse chewed on the wire some years ago. I re-did a couple of the connectors and the electrical tape is gone now. There were no breaks. Anyway, I'm not quite ready to throw in...
  7. RJS3

    Pentair Pool Heater makes a loud bang (backfire?) when it ignites.

    attached is a pic of the electrical. It has the 120 plug and the wires seem in good shape. There are a couple of electrical tape repairs I had to make when a mouse nested in their one winter. I am curious about how to deal with a potential air/gas adjustment @ajw22
  8. IMG_4800.JPG

    IMG_4800.JPG

  9. RJS3

    Pentair Pool Heater makes a loud bang (backfire?) when it ignites.

    I'll address @1poolman1 first. The vent screen is off because I wanted to see if the coils inside and if the chamber was filled with Crud/water. I put my iPhone in an shot some video just to make sure that there wasn't water or anything inside the chamber. Best I can tell, the chamber is good...
  10. RJS3

    Pentair Pool Heater makes a loud bang (backfire?) when it ignites.

    So here is an update to this issue. At the suggestion of @1poolman1 I checked the gas line for water (don't smoke :)), and all looked good. The cap to the gas trap looked brand new, gas flowed out normally and I could not detect any gurgling sounds or water dripping or anything out of the...
  11. RJS3

    Pentair Pool Heater makes a loud bang (backfire?) when it ignites.

    I saw a vid on this very thing. Its worth a try. The Pentair person I talked to suggested that there might be something wrong with the Thermal Regulator. But I'm going to do the gas test first.
  12. RJS3

    Pentair Pool Heater makes a loud bang (backfire?) when it ignites.

    Would opening the gas trap test that, or is that only for debris
  13. RJS3

    Pentair Pool Heater makes a loud bang (backfire?) when it ignites.

    I have a Pentair 200 pool heater on Natural gas. I had turned this heater on when I first opened the pool and it fired up well. Then I decided to power wash it as I was cleaning my deck. Bad idea. I killed the membrane pad. So I vacuumed and cleaned out the inside of the heater (with some...
  14. RJS3

    Another heater question(s)--millivolt or electronic

    Granted, these millivolt heaters are a bit old school. But I have seen a lot of debate on this forum about the cupro-nickle exchangers and I don't live in particularly windy conditions that would require a fan. Again, I'm not looking to have the latest bells and whistles and if I wanted energy...
  15. RJS3

    Another heater question(s)--millivolt or electronic

    I have an in-ground 22,000 gal. pool and I've been nursing an old Tropic Isle 200,000 millivolt heater for the past 4 years or so. It has done the job when it has worked, but this summer, I couldn't get it to work (valve, millivolt, etc. who knows). The exchanger is still in intact (no leaks)...