    1st Test, 1st steps

    Pool Math tells me I need 11lbs of Calcium Chloride to take me from 175ppm -> 250ppm. I'll split applications of it over today and tomorrow. Any concerns with me adding CYA via sock at the same time? I've been averaging 3ppm FC drop per day - pool gets 100% sun. Hoping taking CYA to 50 will cut...
  2. ramahon

    1st Test, 1st steps

    Will be getting CYA to 50 in the next day or two, pending purchase. Copy on pH - was a little surprised to see the .4+ gain. The only thing I can think of is my spa spillover into the pool during the pump / cleaning cycle, otherwise zero aeration right now. Is it recommended or even possible to...
  3. ramahon

    1st Test, 1st steps

    Test from this morning. Hadn't touched MA yet until after these test results. Applied ~40oz of MA to drop pH to 7.4 range. Will test against tonight. FC - 7 pH - 8.2+ TA - 140 CH - 175 CYA - 25 CSI .63
  4. ramahon

    1st Test, 1st steps

    Yup, have a plumbed auto fill. Source of water is t’d off the main in the front of the house and run specifically for pool and irrigation through a separate regulator / backflow. I could do a standalone unit as I have power readily available but we’re on septic, no tie in nearby. Will check out...
  5. ramahon

    1st Test, 1st steps

    We do but I don’t think there is any reasonable way to connect them without an unsightly line across the property. It would be a 120ft run, minimum, with lots of obstructions. Does FC loss become stable enough where I can move to testing every couple of days and rely on a standard add? Or are...
  6. ramahon

    1st Test, 1st steps

    FC - 5.5 CC - 0 Water looks great.
  7. IMG_5214.jpeg

    IMG_5214.jpeg

  8. ramahon

    1st Test, 1st steps

    Appreciate all the help!
  9. ramahon

    1st Test, 1st steps

    pH of 7.2 takes me to -0.37 with all else constant.
  10. ramahon

    1st Test, 1st steps

    Alright - Most recent test. I ran pH, TA and CH twice. Had my wife act as another set of eyes on the pH. Clearly I misread the first round and appears I didn’t take TA to the end as well. ------------------------------------------ Test Results 06-03-2024 @ 08:36 PM...
  11. ramahon

    1st Test, 1st steps

    Appreciate the dialogue on thread. Nice to read through everyone’s thought process. I’ll get FC to 6ppm tonight and then do a full test. I’m fairly certain I took both to the end but we shall see. Testing for OCLT just needs to be after sun down and before sun up, correct?
  12. ramahon

    1st Test, 1st steps

    FC - 1.5 CC - Didn't test yet. pH - 7.2 TA - 110 CH - 175 CYA - Didn't test yet. Step 1: Adding another 30oz of liquid chlorine to bring it to 3ppm. Step 2: Acid to lower TA? Step 3: Aerate overnight to raise pH back up?
  13. ramahon

    1st Test, 1st steps

    My add of 3lbs, 14oz was the pool math rec against 15,500 gallons -> 30 CYA. I was more so thinking about testing for FC levels. Given I added chlorine before CYA was ~30.
  14. ramahon

    1st Test, 1st steps

    Fill has officially finished. 13.5 hours, not too bad. I have the filter and the IFS running for additional agitation. Assuming I test when the CYA was completely dissolved?
  15. ramahon

    1st Test, 1st steps

    Thanks. Adjusting