Recent content by [email protected]

  1. Q

    End of white cell cord keeps burning and melting

    Thanks for asking! We realized that although the computer didn't give us a warning, the cell contacts were bad and transmitting voltage between both contacts, which caused all the cables to melt. We tested it with an Ohms tester. Unfortunately as we didn't know this earlier it cost us quite a...
  2. Q

    End of white cell cord keeps burning and melting

    The computer is an Autopilot Digital and the cell is a model SC48
  3. Q

    End of white cell cord keeps burning and melting

    Thanks Jason, Could it be that the cell connections are bad? The cell seems to still be working fine, however due to the cords burning the connections could be bad, however I assume in that case the computer would tell me that the cell is bad. Is there a way to test the cell? We always made...
  4. Q

    End of white cell cord keeps burning and melting

    Hi, I really need help with this problem. The end of my white cell cord keeps burning. If I pull off the end (the part which pushes on to the cell connectors) inside looks partly melted and it also has some tarry substance inside. It is a big problem as I am already on my 3rd cord and today...
  5. Q

    Warning low amp - cell? What to do?

    Yes the end of the cord was burnt! We did check the board and we could see that some of the capacitors were burnt aswell! We replaced it with a new one and it works fine now!
  6. Q

    Warning low amp - cell? What to do?

    Thanks Jason! Yes I am aware of that and I did get those results after the pump was on for a while. Also just to let you know some black tar substance came out of the cord (the end where the cell plugs in) so we changed the cord. In relation to the warning however I have good news. I took out...
  7. Q

    Warning low amp - cell? What to do?

    I have been having issues as I get the low amps - cell warning. I ran the TEST POOL PILOT which stated that I had 0 volts and only .6 amps (less than one). I tried a new cell. This one is a 42 instead of the 48 which I have had in it and still it is giving me the same warning. Salt levels are...