Recent content by ozdwayne

  1. O

    Aqua Rite SWG Low Salt and Check Cell Errors.

    Yes I am thinking of another warranty claim. You are right. I could do the install myself. Do you know of any electronic / electrical diagnostic info for the control board? ( voltages at test points or at various components) Could one of the bridge rectifiers be failing or the transformer? Or...
  2. O

    Aqua Rite SWG Low Salt and Check Cell Errors.

    I thought that might be possible. The Ti cell is about $250 cheaper than an original T-cell-15. $550 vs $300. Other people seem to have had good luck with the Ti cells. To get a complete new system is around $1700 plus install. Ouch.
  3. O

    Aqua Rite SWG Low Salt and Check Cell Errors.

    Yes that is correct. It does replace the T-cell-15. This is the second Ti cell I have had. This one is the warranty claim one. The previous Ti cell did exactly the same thing. The old T-cell-15 (15 years old) was showing the check cell lamp constantly and not making chlorine. I replaced it...
  4. O

    Aqua Rite SWG Low Salt and Check Cell Errors.

    I had the level tested at the good local pool store. Level was within 100ppm of my measurement. Cell is less than 2 days old. Any idea as to why the amperage is so far below the limits specified in the manual??
  5. O

    Aqua Rite SWG Low Salt and Check Cell Errors.

    I have an Aquarite SWG that has the Low Salt Error Light on and the Check Cell Error light on. I have replaced the cell and still have the same problem. It was 14 years old. I also replaced the Relays and the Current Limiter as described in other threads. The cell generates chlorine for about...