Recent content by nuklhed

  1. nuklhed

    Keypad for Intelliflo pump. 011018 (mfg 2013)

    That kit costs over $800 !! We're just trying to replace a small plastic keypad gizmo. There has to be a workaround ! If there isn't one, instead of spending that much on an old pump, I'll just buy a new model at Amazon for $1150. It's bigger/better too !!
  2. nuklhed

    Pentair Intelliflo LCD screen backlights and buttons work, but nothing on Display

    MANY thanks to Retro Recipes for his YouTube video making perfectly clear HowTo do this job - even the redneck solution to the security Torx screwheads. Marvelous! That set of tips is right on the shelf at Harbor Freight, for next trip! Should have mentioned: No power-off helped, regardless...
  3. nuklhed

    Pentair Intelliflo LCD screen backlights and buttons work, but nothing on Display

    Well, this one is about driving me nuts. Plenty of the issue showing up in online flow, but no verifiable fix other than to completely take aprt, clean contacts, and hope for the best. Sounds like an all-day project without any certainty this backlight constant-on issue ever got resolved...
  4. nuklhed

    Flocculating additive

    My CH is way too high (600+), so I'm considering a flocculating agent. Pool has a cartridge filter. There doesn't seem to be any commentary around this. We are in Las Vegas and our water is very hard. Should I be concerned this agent will permanently clog the filter matrix? Is it true that...
  5. nuklhed

    Vacuum hose stuck in skimmer hole

    I suspect what you've got is a 90-deg ell right out the bottom of the skimmer. When you pull on the hose, it kinks right there, it's a sharp 90. The kink is wider than the bore of the pipe, so you're locked in. Do you have any idea how much hose might be down the pipe? If it's just a foot or...
  6. nuklhed

    Ultraflex 2/ Caretaker 99

    Hello Tom, this is Brian, I am in Las Vegas too. Did you get your issue resolved? I have Ultraflex II and am having a similar issue, and think I am closing in on the solution. Feedback from your experience might shed more light on my issue. I think the rapid-blink results from there being too...
  7. nuklhed

    Ultra flex 2 fails to rotate between stations

    This could be something so simple as a broken wire. Has continuity been checked from end-to-end on all eight conductors? I always start with the simplest things first. Test transformer output with voltmeter. This kind of thing. Many times I've had good luck simply jumping a sensor with a test...
  8. nuklhed

    resource for borax?

    end of SLAM Thanks for followup, y-not. Yup, you betcha we left the pool toys, poles, brushes, etc. in the pool during the process.. the whole time too. Toys are cheap and hose is old so we don't care if there's a bit of... er... 'degradation'? :evil: As for OCLT, I did evening test...
  9. nuklhed

    resource for borax?

    test results, end of SLAM I don't know how to interpret behavior of FAS-DPD test. This morning saw same behavior as many times before. Got nice bright pink color after R-0870, then at 79 drops R-0871 color had gone to very thin pink. At 81 drops barely any color, not really even pink... more...
  10. nuklhed

    resource for borax?

    end of SLAM Yes, I'm fairly certain all criteria as of tomorrow morn. Although not in a tidy straight line. More like a drunk-walk. :cheers: Will test again this evening for that result, then compare. Isn't 20 gals Chlorine over span of 4 days enough?
  11. nuklhed

    resource for borax?

    End of SLAM Okay gentlemen, I am at the end of the Slam process and now wonder how long it will take for the Cl level to come down enough for swimming again. This pool has 5 large jets, would it help 'blow off' the high level of chlorine by running the jets? Otherwise, if I have to wait for...
  12. nuklhed

    resource for borax?

    SLAM reply: Thanks for following, Tech.Guy. Current CYA=80. Yes, I overshot with FC=52, but am still losing fast, and must.alg target=44. I anticipate FC=40-ish by nightfall. I'm still awaiting response from community about softened water. I think this is a worthy thread to follow, for...
  13. nuklhed

    resource for borax?

    couple questions for Chem.Geek Very pleased to observe you're following (even if only at a distance). :oops: Q1: I see you have a variable pump. Did you trace power useage before going to variable? I'm not convinced the savings will be so extreme as sellers allege. Q2: My well water...
  14. nuklhed

    resource for borax?

    SLAM progress Numbers I am seeing are really extreme. Water significantly more clear but still a trace of cloud. Most must.alg suppressed but boyoboy, that stuff sure is tenacious in corners, I'm having to go after it with wire brush. To recap: Started SLAM with 6 gal Cl., two days ago. Test...