Recent content by nanunanu

  1. N

    Getting no flow with new aqua pure 1400

    Did the switching to program B and back to A. Flow starts up again. Then, at some point, could be hours later it goes to no flow. Also, turning system off and then on will start "flow". It really is intermittent. When the system starts up, always goes to flow. Some point later in the day...
  2. N

    Getting no flow with new aqua pure 1400

    So I've gone a full six weeks with no problems. Now back to "no flow". Any suggestions?
  3. N

    Getting no flow with new aqua pure 1400

    Rechecked and it is 02 11 0A 10. 3 months ago I changed out sensor and I've been running program A for about 3 months and have not had problem. No Flow issue didn't show up until a week ago when i changed out the cell. when system initially powers up, flow. it is sometime later in the day...
  4. N

    Getting no flow with new aqua pure 1400

    Now I have changed out the sensor, brand new sensor, worked fine for a while, now getting no flow again. Help.
  5. N

    jandy remote not showing status

    New issue with jandy remote, not showing salinity. It does show "filter pump" when the system is on but the salinity is not showing. Salinity is registering on the main panel and is at 3100. any ideas on how to get the salinity again showing on my remote?
  6. N

    Getting no flow with new aqua pure 1400

    Yes, its the first one that pops up. Program A.
  7. N

    Getting no flow with new aqua pure 1400

    Sensor is about four months old. Cell is about one week. System was put in in 2007. I changed out the sensor today so in fact, as of now, sensor is brand new. Program A is the proper program and is running. Fingers crossed.
  8. N

    Getting no flow with new aqua pure 1400

    Really appreciate your help ping. I changed out the sensor a few months back. I have a new spare sensor that came with the new cell that I installed. As of this morning "flow". Next time I see a "no flow" I'll change out the sensor. Seems like a sensor would last more than a couple of...
  9. N

    Getting no flow with new aqua pure 1400

    I did not use the small adapter board. From my instructions that came with the sensor, "attention installer, this part has changed, you do not need the flow adapter board."
  10. N

    Getting no flow with new aqua pure 1400

    Ok. Possibly I have a different circuit board. I opened the panel. Underneath where the sensor plugs into the circuit board is a small white button. Pencil eraser size. Says salinity over it. Is this it?
  11. N

    Getting no flow with new aqua pure 1400

    I assume the button that says "salinity" is the one to push? By 2 speed pump you mean "on and off"? If so, yes it does not have a variable speed. I also don't see a tiny green LED.
  12. N

    Getting no flow with new aqua pure 1400

    Changed out sensor about four months ago. Changed cell one week ago. Aqua pure 1400. Now getting intermittent no flow. I have read that there is a "reset" button? I see a reset button on the panel. Is this it? Or, is there a reset button on the small adapter piece that connects the flow...
  13. N

    Replacing a PLC1400

    Thank you so much! The pool store thought I was crazy as did Zodiac. Pool store swore it was the exact same part. New ordered PLC1400 should arrive tomorrow and I should be able to drop it in. Thanks again.
  14. N

    Replacing a PLC1400

    Old one is 3 port cell. Might be the other way around as the old 3 port cell unions and existing unions are too big for the replacement the pool store sold me. So, if I am following correctly, the pool store sold me a 3 port cell with the smaller fittings. A new PLC1400 should have the...