Recent content by mridude2017

  1. M

    Raypak 407A ignition failure no pilot sensed

    Replaced the pilot light assembly. Heater is cranking away! Thanks for all the help.:)
  2. M

    Raypak 407A ignition failure no pilot sensed

    Thanks, thats a much better manual than I have. Its definitely not lit, but not sure I can see under there well enough to poke a lighter in there. I will try a better flashlight!
  3. M

    Raypak 407A ignition failure no pilot sensed

    I have looked underneath, used a flashlight, tried everything I can think of and I just cannot figure out where to look to see if the pilot light is lit or not. I see where the gas connects via the small line to the pilot light assembly, but after that I cannot see where to look to see the...
  4. M

    Raypak 407A ignition failure no pilot sensed

    When I set the temp above the current temp the unit display says "spark", I hear a fairly loud click, and it seems like I can feel something in the valve, but hard to say. I also hear sparking BUT, while the spark used to sound like a loud rapid clicking when the unit was working correctly, now...
  5. pool heater serial number and more.jpg

    pool heater serial number and more.jpg

  6. M

    Raypak 407A ignition failure no pilot sensed

    I used the board that Raypak told me was the correct replacement. However it is a little different than the original board. Two of the connectors are installed opposite from the original, but the pins match up if you turn the connector around and everything seems to work correctly. No error...
  7. M

    Raypak 407A ignition failure no pilot sensed

    It is the electronic ignition model.
  8. M

    Raypak 407A ignition failure no pilot sensed

    Maybe this sounds dumb, but I don't even know where to look to "see" if the pilot light is it. I have looked inside/underneath but really don't see where the flame would be. But, when I do get really close to look underneath inside I smell gas faintly... Anyone have a pic of the pilot light flame?
  9. M

    Raypak 407A ignition failure no pilot sensed

    The heater display was doing very weird stuff...incorrect displays and would not even try to spark. I replaced the control board. Now it correctly tries to start up. I can hear the spark. But I get the "ignition failure no pilot sensed" failure. Any help would be appreciated.