Recent content by mpcl3141

  1. M

    APURE35 Ei Check Salt Error

    Here is some additional data from the PDF that I am missing above: Salt • Ocean water – 35,000 to 36,000 ppm. • Tear drop – 7,200 ppm. • Ei – 3,500 to 4,000 ppm. The purer the salt the better. Calcium & Magnesium are enemies of the cell. Pure NaCl • Minimum 98% pure food grade NaCl • No added...
  2. M

    APURE35 Ei Check Salt Error

    I forgot to add that my water temp has ranged from 70-76 ° F during my daytime debugging. I took out the PCB and cleaned it. I was able to read the remaining button text. PB1 Reset PB5 Timer PB2 On/Off PB4 Output PB3 Clock PB6 Hours PB7 Mins A deep Google search with new set of keywords...
  3. M

    APURE35 Ei Check Salt Error

    I have a Jandy APURE35 Ei manufactured FEB 2010. It appears that Jandy (Zodiac) has another type, PLG model with separate sense line pod. I have the single, integrated unit. I just replaced the cell with Zodiac R0511400 35 Electrode for $197. I have confirmed the wiring is connected and correct...
  4. M

    Hello TFP

    First found the PoolSchool three years ago when the family got "me" a 15' circular Intex AG pool for Father's Day. About 2' deep but too much water to empty daily. I was a total greenhorn who was quickly hit with a green pool. ;) PoolSchool and PoolMath saved the day! Fast forward three years...