Recent content by MillennialFinance19

  1. M

    Pentair EZ Touch Problems

    We had bad storms last night including multiple power outages, and I'm fairly certain I lost my EZ Touch mother board again (2nd time). My display is blank and about half of the button lights are stuck in the "lit" position, and the IC-60 isn't running and my pump is on manual. Nonetheless, I...
  2. M

    Pentair IC-40 Mass Confusion

    UPDATE 2,391: After my problems returned again, I didn't do a complete SLAM as I had no idea what the issue was. First, I brought my salt level up to 3,600 from 3,100, which is Pentair's recommended level. Next, I used Orenda PR-10,000 to remove the 390 ppb in phosphates I had. After a few...
  3. M

    Pentair IC-40 Mass Confusion

    Update: I lost 3ppm overnight. No clue how I'm losing chlorine again when I just returned to normal levels.
  4. M

    Pentair IC-40 Mass Confusion

    Alright... I'm back. It took from Sept 5th until now running my SWG at 20% to get back to 6-7. Once I reached that level, I turned it up to 80% and left it. Yesterday, I'm down to 2.5. I added 2.5 gallons of chlorine and went to bed. Just measured it again and I'm at 4 while running the SWG at...
  5. M

    Pentair IC-40 Mass Confusion

    Well, if that isn't proof of the flaws with the ColorQ test kit, I don't know what is. I just tested it with the Taylor kit and got 110!
  6. M

    Pentair IC-40 Mass Confusion

    One more question - I just tested my Alk and it is at 38. It was at 90 when I started this. Should I bring this up now?
  7. M

    Pentair IC-40 Mass Confusion

    9/5 update: OCLT revealed ZERO chlorine loss. I have my SWG off and am letting the chlorine level off. I added enough stabilizer to hopefully bring me up to 80. I'll check this evening and see where I'm at. Thanks for all the help! Hopefully I'm done for now :)
  8. M

    Pentair IC-40 Mass Confusion

    Got it. That would have been great to know. At least I'm not too far off, and I'm sure it could be worse.
  9. M

    Pentair IC-40 Mass Confusion

    Night before last, my drop was 1.5, so it appears I've made some progress. Last night I didn't test as I wasn't home. Hopefully tomorrow morning I have less than a 1.0 drop and I can wrap this up. Question - I'm running the SWG at 100% during the day but am still haven't to add liquid chlorine...
  10. M

    Pentair IC-40 Mass Confusion

    Alright. Evening update (pictures just for visual aid). I came home and immediately cleaned behind both lights. They were spotless (see photo). I also blew a hose into my main drain. I also cleaned the umbrella holder in the swim out - this had a torpedo toy and some green algae. This is...
  11. Pool.jpg

    Pool.jpg

  12. Light.jpg

    Light.jpg

  13. bubblers.jpg

    bubblers.jpg

  14. M

    Pentair IC-40 Mass Confusion

    Thanks. Tonight I’m going to take the bubblers out and ensure the umbrella post is clean.
  15. M

    Pentair IC-40 Mass Confusion

    Thanks, I appreciate the response. Pool has been clear the entire time. I had CC of .5 in the beginning, but that’s gone. I haven’t tested every two hours as I’m working 12-hour days. Tonight I’ll test at 5, 7, and 9 and report back.