Recent content by Megquincey

  1. M

    trouble getting Jandy actuators to work with my Aqualink RS-8

    I finally figured out the problem. I didn't have the cams set up properly. It was either the relative positions of top and bottom were wrong or I hadn't pulled the shaft back up into place. I started from scratch and it all worked fine from there. Thanks for the support! It helps to know there...
  2. M

    trouble getting Jandy actuators to work with my Aqualink RS-8

    No I leave it in one of the On modes. Is the aqua link pcb supposed to automatically recognize the intake and return Jva connections? And if so, simply putting on Spa Mode is supposed to activate the Jva? Sent from my iPhone using Tapatalk
  3. M

    trouble getting Jandy actuators to work with my Aqualink RS-8

    I've just simplified my pool configuration down from two old pumps with separate heaters/filters to one new Jandy VSP for both the spa and pool. Everything is working great but I have run into trouble getting my new Jandy 2444 JVA to work with the Aqualink RS-8 Combo. If anyone has any ideas...