Recent content by mdhwoods

  1. M

    Can I use a SWG in a system with 2 speed pumb and solar

    Was going from memory at work. You are correct, my low is 30gpm and my hi is 60. I have an inline flow meter that I read. Not sure why I thought it was 10.
  2. M

    Can I use a SWG in a system with 2 speed pumb and solar

    Considering putting in a Hayward Aqua Rite 25000 for my 10000 gallon pool. I have a 2 speed pump that runs on low until the solar control calls for heat. Once that happens it will turn on hi and run until it reaches temp. Will this effect the operation of the swg? Flow rate on high is about...
  3. M

    New Pool Owner (Almost) Now with pictures!

    cya takes about a week to show on the test, don't backwash or clean the filter for at least a week.
  4. M

    2 year old whisperflo pump with problem.

    Ill pull the back cover off this weekend and see how easy it spins. I can tell you i bought it 2 years ago November. Maybe ill have a case with them if it turns out to be a bad motor. I bought it off amazon.com. It was sold by amazon and not a 3rd party.
  5. M

    2 year old whisperflo pump with problem.

    I suspect it is the one on the left as there looks to be a bump on the back and my wiring terminals also look like that if memory serves me right. Caught a cold so probably won't look to much into it tonight though I took a picture of the label. From what I can tell pentair only give a 1year...
  6. M

    2 year old whisperflo pump with problem.

    Sounds good, got home late last night. ill get a picture of the label and pull the cover and see how easy it turns.
  7. M

    2 year old whisperflo pump with problem.

    Thanks for all the input. It is 220 and looks just like that picture. I changed to capacitor under the bump as I thought that was the start. Voltage is fine as it runs on high as long as it is already running on low. Just won't start from high. I'll pull the motor apart this weekend and see...
  8. M

    2 year old whisperflo pump with problem.

    My 2 year old 1.5hp 2speed pump has a strange problem. It will start on low but not on high. If I try to start it on high it just hums then pops the thermal protection. Starts fine on low and runs on high just fine as long as it is already running. Suspected start capacitor, swapped it out...
  9. M

    Life expentancy of plaster

    Calcium has always been around 350 and ph I maintain to the best of my abilities. Adding acid once a week or so. It likes to rise even with my TA around 80. so in 02 it was showing a lot of wear on the steps and this is 2011. I would say it is well over 10 and that I just need to suck it up...
  10. M

    Life expentancy of plaster

    Bought our house in 02 and there was some patching of the plaster done on the steps. Rest of the pool looked solid albeit a bit of discoloration in the plaster on the bottom. Fast forward to today and it seems that i have quite a bit of de-lamination happening just below the water line tile...
  11. M

    BBB / Having to add 64 oz of bleach everyday - normal?

    I live in Sw Florida and add around 36oz of 12.5% a day. My pool is also a 10k gallon. Family like the temp around 86 so that causes a bit more chlorine usage. You are using about the same as me.
  12. M

    replacing 1hp pump with 1hp whisperflow 2 speed.

    So I ended up buying a whisperflo 2 speed 1.5hp pump. I contacted Heliotrope HelioMatic the manufacture of my solar controller as they have 2 models, one that will put the pump in hi when calling for solar and one that doesn't. They are kind enough to take my 4000 controller which doesn't...
  13. M

    replacing 1hp pump with 1hp whisperflow 2 speed.

    i will have to look into my solar control and see if it can do that. It is automated and controls a 24v Jandy valve. i suspect worse case i could design a 24v relay circuit that turns the pump on hi when it call for solar.
  14. M

    replacing 1hp pump with 1hp whisperflow 2 speed.

    When the solar turns on does it automatically switch to hi? Thanks
  15. M

    replacing 1hp pump with 1hp whisperflow 2 speed.

    I know but at twice the cost can I justify it. If i was to use a variable speed would it automatically increase the flo rate when the solar panels turned on and decrease it when they went off? Or do i have the buy that addon controller to do that? I wonder if i could design a circuit that...