Recent content by MattyJ

  1. M

    First Water Test - Now Taylor 2006C

    Before finding TFP I bought a large container of Tabs so... I have two scenarios where I will plan to use them. 1) To slowly raise my CYA to the recommended SWCG levels (so I don't have to buy CYA) 2) To cover times when I'm away on vacation or won't be able to check my pool for a few days. I...
  2. M

    First Water Test - Now Taylor 2006C

    I took them out when I turned the pump off yesterday and put them in a cup that I'll keep by the pump switch. I put them back in the skimmer when I turned the pump back on this morning. Is leaving tabs in the skimmer an issue if I need to be gone for a week? Two weeks? Or is it just a long term...
  3. M

    First Water Test - Now Taylor 2006C

    10 hours of running (from roughly 7 am to 5 pm) raised my FC from 4.6 to 5.0 Sunny day again today.
  4. M

    First Water Test - Now Taylor 2006C

    Impromptu Overnight FC Loss Test last night. FC 5.2 --> 4.6 CC 0.2 --> 0.2 I dropped two Trichlor tablets in my skimmer to start inching my CYA up to recommended SWCG levels.
  5. M

    First Water Test - Now Taylor 2006C

    The day of the SWCG has finally ended. I started at 730 this morning with a FC and pH test FC 2.6 CC 0.0 pH 8.0 Added ~44 oz of 31.45% Muriatic Acid and let the SWG / pump run for 16 hours. Had about 12 people in the pool for about 2 hours late in the afternoon. After all that: FC 5.2 CC 0.2...
  6. M

    First Water Test - Now Taylor 2006C

    That's 17.5 hours if my PoolMath calculations are correct o_O
  7. M

    First Water Test - Now Taylor 2006C

    I'm continuing on the SWG journey here, trying to find my way with how long to run the SWG. I doubt I'll ever run the pump MORE than the SWG and so I have the SWG set at 100%. If you look at my logs I ran my Pump/SWG a total of 10 hours yesterday because my FC wasn't keeping up. Running it 8...
  8. M

    First Water Test - Now Taylor 2006C

    Not only that, but I didn't have to replace the TCELL-15. I speculate that the original system was installed in 2006 with a TCELL-5 (as the board was configured that way) and when it reached end of life, the owner "up-sized" to the TCELL-15 which then didn't work with the board. I'm guessing...
  9. M

    First Water Test - Now Taylor 2006C

    Tested this morning at 07:00 am FC 3.6 CC 0.0 pH 7.8 SALT 3000 Ran the Pump / SWG for 5 hours with SWG at 100% PoolMath says I should have added 1.2 ppm FC but I don't know how accurate my pool volume calculation is. I only added 480 lbs of salt to get from 200 ppm to 3000 ppm and pool math...
  10. M

    First Water Test - Now Taylor 2006C

    I'll do another actual salinity test tomorrow morning, but based on what I have it would be: 2900/3000 = 96.67% How much does salt fluctuate over time?
  11. M

    First Water Test - Now Taylor 2006C

    I just performed possibly the worst solder job in the history of man... but here are my new diagnostic numbers! 2900 80 26.0 6.08 100P -2900 AL-0 r1.40 Actual Salinity tested yesterday was 3000 Cell voltage looks to be slightly high right? Is my next step to test to see if we are actually...
  12. M

    First Water Test - Now Taylor 2006C

    I totally agree.. I've absorbed a lot of information in a short period of time and it has all been gold. I'm too established in my own career to think about a pool service (even as a side hustle), but maybe I'll pass this knowledge along to my young sons when they are old enough and they can...
  13. M

    First Water Test - Now Taylor 2006C

    Blue Haven Pools was the installer of this pool and the timeframe matches. Any clue why a T-5 would have been chosen for a pool of this size? Were the larger cells not available at that time?
  14. M

    First Water Test - Now Taylor 2006C

    Does the model number or the photo of the main board reveal when it was manufactured? With a TCELL-15 from 2010 but a board that is only configured for TCELL-5 I'm wondering if this was a DIY SWG project. (There is also the Oxidizer that has a huge hole rusted through it that isn't hooked up...
  15. M

    First Water Test - Now Taylor 2006C

    Seems pointless if all it can use is a TCELL-5 since I have a 30k gallon pool. I'm up for an adventure... but haven't done any soldering since HS shop class... what do I use to connect the two points? Am I trying to install two pins so a jumper can be used? or just getting a piece of metal...