Recent content by Mandreake

  1. M

    Salt level calibration

    Is there a way to calibrate my salt level readings on my Zodiac APUREM system? One day it reads 3.1 and the next day reads 3.5.
  2. M

    Service needed light and Error codes 172, 186, 186 and HH

    Seems to be working fine right now. The photo I posted had a connection with an older style sensor with 3 visible contacts with the water at the chlorine generator. That type required a Tri-sensor Adapter to be in place when connecting to the board. The newer style sensor which I just...
  3. M

    Service needed light and Error codes 172, 186, 186 and HH

    I ran all the tests on the board and it passed them all exept one for the Cell Voltage and Current. It was supposed to be around 22 volts and I ended up with 11.5. The fix to that was "change the PIB". I changed the sensor and cord, tested it again and got the same reading although everything...
  4. M

    Service needed light and Error codes 172, 186, 186 and HH

    Thanks for the information Ping, but my board is nothing like those found in that pdf file. I do have test points as shown in the image I've uploaded, but they are not labeled the same or in the same layout. To try that without some sort of clearer instructions would be a guess I think. I...
  5. IMG_4735.jpg

    IMG_4735.jpg

  6. M

    Service needed light and Error codes 172, 186, 186 and HH

    That pdf file appears to be used to test a AquaLink system. Mine is a APUREM AquaPure. I do not recall any front board or back board but one board. Here is a photo of my panel.
  7. IMG_4734.jpg

    IMG_4734.jpg

  8. M

    Service needed light and Error codes 172, 186, 186 and HH

    I had the salt level checked today and it is at 3100 ppm. Does that troubleshooting guide in that pdf give me significant instructions on how to test the sensor?
  9. M

    Service needed light and Error codes 172, 186, 186 and HH

    That's odd. I am having to refill the pool about once every 5 to 7 days due to evaporation so I kind of doubt that the salt is high. Maybe the salt level could be high as it probably does not evaporate with the water. I'll have it checked to make sure. I also get this reading when I press...
  10. M

    Service needed light and Error codes 172, 186, 186 and HH

    My Aquapure system is giving me some codes regarding a flow sensor service (172, 185, and 186) and when I press the temperature button I get a HH code which my installation manual says that "Input has exceeded Maximum Range" whatever that means. On another thread I noticed that someone else...