Recent content by m1k_3

  1. M

    Hayward SP32950VSP Pump randomly stops running without any alarm or error

    My pump randomly stops running. Typically in the past if this has happened I get a low flow alarm. I am not seeing any alarms on the pump or on my omnilogic panel. If I go to the the pump diagnostics there are no errors. When this occurs I can just start the pump up again by going to the...
  2. M

    Pump only fully Primes when Sand Filter is put in backwash and will slowly lose prime when in filter mode

    Maybe something simple like your o-ring on the filter basket lid?
  3. M

    Pump only fully Primes when Sand Filter is put in backwash and will slowly lose prime when in filter mode

    I haven't bypassed my filer yet. I was thinking of doing that to isolate the problem. My pump will not fully prime if my filter is in filter mode or recirculate mode. The only way I can get the pump to fully prime is if I put my sand filter in backwash mode. If I fully prime my pump in...
  4. M

    Pump only fully Primes when Sand Filter is put in backwash and will slowly lose prime when in filter mode

    I have been having ongoing issues with my pump staying primed. I thought it might be on the suction side but I think I have proven that is not the case. I can fully prime the pump when the Sand filter is put in backwash. Once primed if I move the filter back to filter mode my pump will lose...
  5. M

    Hayward SP32950VSP Operating Normally?

    Called Hayward support and the person I spoke to said it should be fine and its okay not to completely fill. I am at a loss. The heater is not complaining of flo issues. I guess I will leave as is and hope for the best.
  6. M

    Hayward SP32950VSP Operating Normally?

    I have a hayward S-244T sand filter. I tried setting to recirculate and the pump still does not fill when priming. It is set to a 3 minute prime cycle. I have shut the pump off and cleaned out the pump basket but I have not felt inside the pump. I will try this today. The only input to the...
  7. M

    Hayward SP32950VSP Operating Normally?

    I have lubed my o-ring. This is a brand new pump and first time being used this year. I checked the drain plugs and they seem fine. I have even run water over intake joints plugs and pump lid. No luck finding where the problem is.
  8. M

    Hayward SP32950VSP Operating Normally?

    I do see some small bubbles at the returns. At times there are more bubbles than others and I can visibly see them at the surface as well. I have a hayward S-244T sand filter. I don't think it has an air bleed.
  9. M

    Hayward SP32950VSP Operating Normally?

    Below is a video of this pump running at 55%. The top of the video is the suction side. The water level is basically at the top of the water intake pipe in the pump. New video by Mike Major Below is a video of the pump after it has been priming for a couple minutes. New video by Mike...
  10. M

    Vinyl Over concrete pool. Cracks in concrete with water coming in through cracks

    No rain for days. We are just on a high water table. They ripped out the liner because it did not install properly later year so that was already going to be done prior to having the floating liner issue. The french drain is as deep as the steal walls. Approx 42 inches and trenched to the...
  11. M

    Vinyl Over concrete pool. Cracks in concrete with water coming in through cracks

    This is a concrete pool and yes only built 1 year ago. I linked a video. New video by Mike Major They have dug a trench with a gravity line to the back the yard. Only concern is that it not deep enough.
  12. M

    Vinyl Over concrete pool. Cracks in concrete with water coming in through cracks

    One other question. What equipment is being used to dig well points? Is it possible to do with an auger if you want to go approx 10 feet deep?
  13. M

    Vinyl Over concrete pool. Cracks in concrete with water coming in through cracks

    Our Vinyl liner was floating and the PB removed our old liner. Around the perimeter of the deep end about three to four feet above the bottom there is a crack and water is flowing in. This pool was just installed last year and has not been used. The PB has dug a trench and we have put a sump...
  14. M

    Wellpoints in climates that freeze

    Thanks for the replies!
  15. M

    Wellpoints in climates that freeze

    I live in Ottawa Canada on a high water table. We have had an issue with a floating liner. I have been looking into wellpoints as a possible solution. Do pumps in well points connect to a permanent discharge line and do they run all winter? Anybody know of anybody in the Ottawa area that...