Recent content by luckyc1423

  1. L

    Water Sucking back through returns - any idea why?

    A friend of mine has a swimming pool with a infinity catch basin. The infinity catch basin has its own pump that sucks from the bottom of the basin and sends water through large returns that go to the pool. (so sucks from basin and dumps into pool). The pool has a seperate pump just for the...
  2. L

    Inifinity Edge Pool - Autofill Question

    Just trying to educate myself on intinity edge pools as i have a friend looking at one and i would love to help him. We have the calculation for the catch basin size to include surge...etc... My question is on the autofill. Obviously the autofill goes in the basin. My question is below. 1)...
  3. L

    Pump Loosing Prime issue

    we have the pentair 011056 (3hp variable speed) ok ill test reducing rpm for prime.
  4. L

    Pump Loosing Prime issue

    We do not have a weir door we left ours off. Water halfway up skimmer opening. 1) do you think it’s a clogged line which prevents it from primiminf correctly? 2) is it a air bubble? 3) does the line go dry completely which is why water comes our so quick once we stick our hand over it? As...
  5. L

    Pump Loosing Prime issue

    Ok here is the latest update. Everything started working fine on its own. We had leak detection come out to make sure there was no leaks and of course there was no air bubbles happening at the time they came out (that was 2 weeks ago). in the last 2 weeks everything worked flawlessly up until...
  6. L

    Pump Loosing Prime issue

    Gotcha. I am out of town going to try this tonight when i get Home. My wife has been messing with it. At 2,500 rpm’s it almost stayed completely full of water all night long. Maybe 1” of air ok the top of basket so still slowly letting air in at the higher rpm
  7. L

    Pump Loosing Prime issue

    Which means it would allow air in the lines vs higher rpm?
  8. L

    Pump Loosing Prime issue

    I thoight Of that and just had water come in from floor drain snd the basket wouldn’t fill back up. So not specific to the skimmer. Just weird if it’s a air intake issue that it would happen only at lower rpm
  9. L

    Pump Loosing Prime issue

    Thank you I’ll do that tomorrow and see. It’s a Pentair variable speed pump 011056 Your thinking at lower rpm’s it’s letting air in the system? What wouldn’t that happen at higher rpm’s?
  10. L

    Pump Loosing Prime issue

    quick update. I just turned it off adn restarted. the pump primes flawlessly and primes at 3,400 rpm's once the prime stage is over pump goes to 1,800 rpm's. within 20 minutes pump basket is half full of water. I increased rpm's to 2,500 to see if water would fill back it (prime again) and it...
  11. L

    Pump Loosing Prime issue

    Newly installed pool and pump. for the first two-three days the pump primed and stayed prime the entire time. Today i noticed the pump had no water in it so it lost its prime and i shut it off. i then restarted it and it primed without issue but 2 hours later lost the prime again and the pump...
  12. L

    Intellicenter - I8PS - do i have enough slots?

    I must be missing it then. do you know what the part number is? this it? P/N 522038Z hoping thats not it as i dont see that to be in stock near me.
  13. L

    Intellicenter - I8PS - do i have enough slots?

    is this different than the "daughter" cards that add relays i assume? Reading the quick referrence guide posted my myazpool, is this the right part number? Serial COM Port Expansion Board (Port Multiplexer) (P/N 520818)
  14. L

    Intellicenter - I8PS - do i have enough slots?

    I probably made the system more complicated than it needed to be but in my mind it made sense. I know people hate chlorine but this is what we went with. my plumber doesnt normally plumb pools the way we chose to do it, but i was adamite i wanted it this way. Hopefully it all works as expected...
  15. 1627786458102.png