Recent content by Joey Finnegan

  1. J

    Hayward Aqua Plus Blows 20 amp fuse

    I’ll have to get the pics tomorrow but I definitely will. Thank you! I was curious what pins to check on the cord from the cell to see if I had a short in the cell.
  2. J

    Hayward Aqua Plus Blows 20 amp fuse

    I’ll have to get the pics tomorrow but I definitely will. Thank you!
  3. J

    Hayward Aqua Plus Blows 20 amp fuse

    So if I understand this schematic the salt cell is probably not shorted (a lot of YouTube said it could be the salt cell). I assume the rectifiers are changing ac to dc, correct? So I’m an auto tech and understand DC automotive circuits but I’m rusty on ac such as transformers. What is the fuse...
  4. J

    Hayward Aqua Plus Blows 20 amp fuse

    I have a Hayward Goldline Aqua Plus that says “no cell powe 1”. I pulled the board and verified the relay solder joint was good. Found the 20 amp was blown. I replaced it, powered everything back up and as soon as the salt cell started the fuse blew again. The pump runs fine but there is a delay...
  5. J

    Hayward Aqua Plus Blows 20 amp fuse

    I have a Hayward Aqua Plus. The screen read no cell power. I removed the board and checked the common relay “bad solder” connection and it looked fine. I then found the 20 amp fuse blown. I replaced it and powered up. As soon as the salt cell kicked on “pop”, it blew the fuse again. Where do I...