    Backwashing this DE Filter

    Howdy all, I have a DE filter assembly with a filter currently running in it. It does a good job cleaning the pool; however, after every morning startup it shoots a bunch of sediment into the pool. As far as I know, this is because I need to backwash the filter. I know that under normal...
  2. IMG_1758-min.jpg

    IMG_1758-min.jpg

  3. IMG_1757-min.jpg

    IMG_1757-min.jpg

  4. IMG_1756-min.jpg

    IMG_1756-min.jpg

  5. IMG_1755-min.jpg

    IMG_1755-min.jpg

  6. H

    Issue with Resilience Salt Water System

    I've got my salt system fixed! American Spas and Pools Systems (the owners of Resilience now) told me that a flashing Red Light on your On/Off button on these units can be caused by either A) Too Low Salt or B) Bad Salt Cell. I replaced the Salt Cell and got my Salt Levels to 3500ppm and it...
  7. H

    Issue with Resilience Salt Water System

    Update 2: We removed the Salt Cell from the line, cleaned it in a mixture of 10:1 Water/Muriatic Acid. Also checked and cleaned connectors on the salt cell and the in-line sensor.
  8. H

    Issue with Resilience Salt Water System

    Update everyone: I've got the actual unit turning on. I had to replace the fuse, I guess they're capable of shocking you really good even though they're busted. Oops, however; we're still not working yet it seems. When the unit turns on, I can set the Chlorination value I want, however; the...
  9. H

    Issue with Resilience Salt Water System

    Hello Everyone, We've recently moved into a home that has a salt water system. It appears, however; that the system isn't actually running. From what we can see, the panel itself isn't turning on. It looks like we're running a Resilence SCC-25 salt water system. Attached is a photo of the...