Recent content by hamw

  1. H

    DE error, SWG blank panel, board beeping, iAqualink unstable.

    James W, I just saw these posts after making my post regarding the board replacement. I appreciate your extra advice. In what circumstance would one need to use this procedure? Is that to test the actual front board with the LCD panel and the A/B buttons, salinity, etc.?
  2. H

    DE error, SWG blank panel, board beeping, iAqualink unstable.

    So after reading through the referenced links and doing a little bit more digging, I went ahead and got a new aqua pure controller board from Sunplay, for around $209. Just got finished replacing it. That seems to take care of the issue completely. My only hiccup was that the RS8 LCD controller...
  3. H

    DE error, SWG blank panel, board beeping, iAqualink unstable.

    Thank you, good suggestion. I’ll do that and point them to this thread. And the meantime, any other thoughts would be appreciated.
  4. H

    DE error, SWG blank panel, board beeping, iAqualink unstable.

    I am guessing this is an AquaPure board problem. Basically I was unable to hook to the iAqualink a few weeks ago. I checked the equipment and a dE error was on the AquaPure panel. Currently the display is blank unless the A and B buttons are pressed. I checked the TFP forum, and this appears to...
  5. Jandy 60.jpg

    Jandy 60.jpg

  6. Jandy 08.jpg

    Jandy 08.jpg

  7. Jandy LO.jpg

    Jandy LO.jpg

  8. Jandy dE.jpg

    Jandy dE.jpg

  9. Jandy PLC1400 SN.jpg

    Jandy PLC1400 SN.jpg

  10. Jandy RS8 Rev T2G.jpg

    Jandy RS8 Rev T2G.jpg

  11. H

    Raypak 407a enx vs 408a enx?

    I have a 406 a. It has died by virtue of rusting out in the bottom. There have been a lot of posts about these water heaters. Nonetheless, we got eight years out of it so I guess that is pretty good. I’m now needing to look into a new pool heater. There is a 407a and a 408a. The 408 is a...
  12. H

    Pool Remodel leads to leak. Seeking solutions

    Any further update on these? I am looking to refinish my pool and the eco-finish seems like a good idea, but sounds like it needs extensive prep work.
  13. H

    Adding Relay to Jandy Aqualink Power Center

    Was wondering if this is in fact the way to go. I also have a camera and router that I'd like to be able to reboot remotely. Confirmed success?
  14. H

    Water flow meter by Rola-Chem

    Thanks for the reply. I'm sure I don't really understand the issues involved, but have looked at a bunch of threads re estimating flow rate based on tubing diamter, bends, filter pressure and vacuum to calculate total head. I think most pools like mine, in ground pool/spa combo, wind up around...
  15. H

    Water flow meter by Rola-Chem

    I am in the market for a flowmeter as I have recently installed a variable speed pump. The rola chem seems attractive as it will read to a lower flow than the blue-white, 20 vs 40. If anyone has an updated experience with these two brands, could you post your thoughts? Sent from my iPhone...