Recent content by HackerPool

  1. H

    Intelliflo RS-485 disconnected but still "DISPLAY Not Active"

    Turned off pump from Aqualink. Turned off power supply to pump. Pulled RS-485 from side of pump. Pump display said Power interrupted (or something close). Turned power back on (with cable disconnected) - back to original Display Not Active message (in first picture). Update: turning off...
  2. IMG_7214.jpeg

    IMG_7214.jpeg

  3. IMG_7215.jpeg

    IMG_7215.jpeg

  4. IMG_7216.jpeg

    IMG_7216.jpeg

  5. H

    Intelliflo RS-485 disconnected but still "DISPLAY Not Active"

    I want to see the settings on my Pentair Intelliflo VSF (it is connected to an Aqualink RS & iAqualink controller) but the display on the pump says "DISPLAY Not Active!" I've tried temporarily disconnecting the RS-485 but it still says "DISPLAY Not Active!" None of the buttons does anything...
  6. H

    Time to replace Hayward T-Cell-9?

    Update: I noticed the No Flow light was starting to stay on, rather than blink and turn off after starting pump. Replaced my flow sensor (old one was 10-12 years old and had some buildup on it) and there may be some life left in the cell. Normal readings and chlorine generation for about 24...
  7. H

    AquaRite - sudden 0 ppm reading

    Is the power light on on the controller? If not, then the thermistor is the likely problem.
  8. H

    Time to replace Hayward T-Cell-9?

    My Hayward/AquaRite T-Cell-9 appears to be failing (it's about 6.5 years old) and I'd like a second opinion. Readings on salt have been all over for the last week or 2 (from 700 to 2800 with instant between 0 and 3100, store test showed 2800). It appears to work with sane readings (including...
  9. 04ADB942-B00C-401A-A39E-7F1F667EEABF_1_105_c.jpeg

    04ADB942-B00C-401A-A39E-7F1F667EEABF_1_105_c.jpeg

  10. july_t_9.jpg

    july_t_9.jpg

  11. H

    Air bubbles in return and pump basket

    @mknauss I tried that today for about 2 hours and the bubbles did decrease (not quite gone, but mostly). They came back about 10-15 minutes after I turned the SWCG back on. It's way more than I've seen in the past, but I'll keep an eye on it and try this again to verify. Thanks!
  12. H

    Air bubbles in return and pump basket

    I have bubbles in one of my returns and would like some help determining the source. I recently replaced my pump and added the iAqualink. The bubbles were there before and I was hoping the new pump and plumbing would resolve it. When I run in spa mode, there are no bubbles at the spa returns...
  13. H

    New Jandy/Zodiac Spa Side Remote w/ Aqualink RS4 - button 3 not working

    Closing the loop on this: I ended up replacing the controller board (see other post - I got an MM revision, which does not work with non-Jandy SWGs - BOO JANDY! - replaced the chip on it with a JJ to resolve the SWG issue) and the switch is now operational (all 4 buttons + LED). Thanks to all...
  14. H

    Aqualink not recognizing Aquarite

    Closing the thread - I was able to get a JJ chip and install it on the board. All working, Aquarite, spa switch, indoor controller.