  1. G

    Mastertemp 400 no ignition, low voltage to igniter

    Hi! Thanks for the replies. Ill cut to the chase. > Check that the igniter resistance is 50 ohms. Measured 68.5 ohms on the one i removed. Checked the new one I just put in, shows 0 ohms... Pulled it out, the entire center section is missing :smh: I was super careful putting the new one in...
  2. G

    Mastertemp 400 no ignition, low voltage to igniter

    My ~2016 MasterTemp 400 suddenly stopped igniting. Normal no ignition, I smell gas, hear click, etc. No puff of heat, no sound of ignition. It wasn't getting hot anywhere around the igniter, as measured with an infrared thermometer, so I assumed it was the igniter and ordered a new one without...