Recent content by gratefulmjc

  1. gratefulmjc

    PCC2000 Valve Module Repair Journey

    Hi @kdrob. Several years ago, when I got tired of spending the $$$ for replacement Valve Modules and telling myself there must be a way to repair them, I poked around the internet but didn't find any replacement parts. Curious after reading your post, I poked around again and saw this on eBay...
  2. 32_ImpellerHeld.jpg

    32_ImpellerHeld.jpg

  3. gratefulmjc

    PCC2000 Valve Module Repair Journey

    C. In order to press the Impeller Gear completely onto the Impeller Shaft, I set the Valve Module on its side and used a screwdriver against the root of one of the blades of the Impeller to keep the Impeller Shaft from moving downward while I pressed downward with the ball of my thumb on the...
  4. gratefulmjc

    PCC2000 Valve Module Repair Journey

    7. I removed the remaining three components in the Valve Chamber by simply taking them out. First the Bellows Cap. Then the Valve Head (note the Valve Head has to be rotated to the proper orientation in order to remove it from the Valve Module...from the bottom). Lastly the Bellows. The...
  5. 18_BellowsAssemblyWasher.jpg

    18_BellowsAssemblyWasher.jpg

  6. 19_ValveRemoved.jpg

    19_ValveRemoved.jpg

  7. 20_BollowsRemoved.jpg

    20_BollowsRemoved.jpg

  8. 23_BellowComparison.jpg

    23_BellowComparison.jpg

  9. 21_DisassembledUnit.jpg

    21_DisassembledUnit.jpg

  10. 24_BellowsInstalled.jpg

    24_BellowsInstalled.jpg

  11. 25_ValveInstalled.jpg

    25_ValveInstalled.jpg

  12. 27_ValveOrientation.jpg

    27_ValveOrientation.jpg

  13. gratefulmjc

    PCC2000 Valve Module Repair Journey

    4. I removed the Gear Table Disk by simply lifting it off the Impeller Shaft and, without disturbing the gears, placed it out of the way to avoid knocking it over and scattering the gears during the following steps. 5. I removed the Valve Chamber Cap from the problematic Valve Chamber by...
  14. 10_GearTableRemoved.jpg

    10_GearTableRemoved.jpg

  15. 11_RemoveChamberCap.jpg

    11_RemoveChamberCap.jpg