Recent content by g0yanx77

  1. G

    Hayward Tcell940 - Low Salt

    Thanks again, James. I'd like another salinity test, since the Taylor K-1766 shows 3600 and the Hayward controller says 2200. What would you recommend for a new salinity test? I did order a Taylor K2006 complete test kit, so I'll work on the CSI.
  2. G

    Hayward Tcell940 - Low Salt

    Appreciate all of the help! Diagnostics readings from this morning: Tcell940 serial = 4E21125-201648 AquaRite 940 serial = 4A21125-103132 Controller set to OFF position 2600 87 33.6 0.00 95P -0 AL-0 r 1.59 t-15 Controller switched to AUTO from Off: 2600 87 27.8 5.71 95P -2200 AL-0 r 1.59...
  3. G

    Hayward Tcell940 - Low Salt

    Thanks, James! Cell says 940 on the label. Serial is 4E21125. I will get the serial off of the controller tomorrow and update this post. I will also get readings after resetting, per your instructions above. Salinity was measured with K-1766 today - 18 drops = ~3600ppm. Cell efficiency quick...
  4. G

    Hayward Tcell940 - Low Salt

    Hello fellow pool enthusiasts! Long story short...our 20x40 pool was installed a few months ago. An AquaRite 900 and Tcell940 were installed at that time, and the system always reads low salt when the correct cell type (T-15) is configured. My installer changed the cell type to T-9, and stated...