Recent content by FaustFamilyPool

  1. Faust Family pool

    Faust Family pool

  2. FaustFamilyPool

    Intellichlor IC 40 Corroded (melted) spring steel on flow switch

    Thanks for the welcome! I’ve been following the TFP site for two years now, but haven’t had a need to post. Yes this is a tricky one. I think the Hayward auto chlorinator is somehow releasing highly chlorinated water into the vicinity of the flow switch during shut down. My next step is to...
  3. 84F59CDF-6A84-4E8F-A28C-CCE75744AD00.jpeg

    84F59CDF-6A84-4E8F-A28C-CCE75744AD00.jpeg

  4. 20CACC1E-76A6-4FA3-9D78-ED5E21F70E51.jpeg

    20CACC1E-76A6-4FA3-9D78-ED5E21F70E51.jpeg

  5. FaustFamilyPool

    Intellichlor IC 40 Corroded (melted) spring steel on flow switch

    High. I’m having an issue with my IC40. it keeps eating up the flow sensor spring steel. I posted my water chemistry below. I cannot figure out what is going on. Here are some of the details. I am having an ongoing issue with the spring steel on the flow switch failing. I’m looking for some...
  6. 6F4D8319-1541-470A-8F66-4974F2F70C26.jpeg

    6F4D8319-1541-470A-8F66-4974F2F70C26.jpeg

  7. F4789514-0D04-4B75-80A6-C44BD26D7A3D.jpeg

    F4789514-0D04-4B75-80A6-C44BD26D7A3D.jpeg

  8. 3704EDAF-D6B3-4348-958A-7DB757FF9FF4.jpeg

    3704EDAF-D6B3-4348-958A-7DB757FF9FF4.jpeg

  9. Faust Pool

    Faust Pool

  10. Salt cell piping

    Salt cell piping

  11. FaustFamilyPool

    Intellichlor IC 40 Corroded (melted) spring steel on flow switch

    I am having an ongoing issue with the spring steel on the flow switch failing. I’m looking for some advice on what the issue could be. Here’s what’s happened thus far: - IC40 was installed - After about 4 weeks the sensor failed. - I ordered a new one on Amazon. Pentair factory replacement. - I...