Recent content by DR87

  1. D

    Help with part/name for backwash/waste water exit valve hole

    I'll check this out, I thought it was maybe something like that, but wasn't sure. Appreciate the help!
  2. D

    Help with part/name for backwash/waste water exit valve hole

    I've got a Heyward Pentair filter for an 18k gallon pool we inherited with the house we bought last August. When I backwash I have to put the hose over the exit valve hole and clamp it down with a metal adjustable ring. Not to mention I have to stretch the hose quite a bit to get over the little...
  3. D

    Time for a new PCB?

    Well, just got done soldering in the new thermistor and got it all hooked up and back in. Lights came right back on! Salt reading has began going up. Lights no longer shutoff and no "click" is heard. Def appears that was the problem, I'll keep an eye on it for the next few hours but I think Im...
  4. D

    Time for a new PCB?

    Seems to be what Im landing on as well per my research. $9 from amazon + a new soldering iron because I have no idea which box my old one is in ($20) which will be here today/tomorrow. Sounds a lot better than $500.
  5. D

    Time for a new PCB?

    Thanks for the reply! It def looks old, but not cracked or flaky, tapping it a few times didn't change anything where the voltage climbing to 17 lights come on and voltage climbs up before crashing and then the lights go off. Board works fine otherwise (so it appears). Pool store says the board...
  6. 20220829_120142.jpg

    20220829_120142.jpg

  7. 20220829_120213.jpg

    20220829_120213.jpg

  8. 20220829_120204.jpg

    20220829_120204.jpg

  9. 20220829_120138.jpg

    20220829_120138.jpg

  10. D

    Time for a new PCB?

    Hi All, Im a new SWG (cell is new as of this season) pool owner as of mid-august and I've inherited a bit of a lemon... Minor details, I live in STL Missouri and we had horrid flooding at the end of July, former owner got the pool "cleaned" prior to closing but I later found the filter (DE...