Recent content by Dr Dave

  1. D

    Auto pilot Nano- low volts/high amps

    Thank you all. Thanks for the tip on CYA and I'm using dichlor. I will dilute the pool. Is Calcium Hypochlorite acceptable? I have this issue frequently up north using stabilized pucks. Any suggestions other than a SWG? Boost indicates 2v, 9.6a, 84F, 3200ppm Shifted cell cable along cell...
  2. D

    Auto pilot Nano- low volts/high amps

    Thank you for your quick response. Pool looks fine because I am shocking once a week. Today : Total Chlorine 1.0 Free " 1.0 Combined 0.0 PH 7.5 TA 100 CYA 100 Salt 3200 I have 2 pools; inground vinyl up north for 26...
  3. D

    Auto pilot Nano- low volts/high amps

    I have owned this unit for 3 years with considerable issues. The warranty period is now over. When the unit ran properly and produced chlorine , volts were normally 14-15 and amps between 5-6 . Now it produces virtually no chlorine and reads 10 amps and 5 volts, nearly the reverse of previous...