Recent content by dlnagold

  1. D

    DE filter issue

    Thanks, had to unexpectedly go out of town, I will run those tests and post as soon as I get back. I don’t think it is any kind of Alger growth because we just drained the pool, had it resurfaced and it is doing the same thing at startup. I have put de powder in the skimmer, this time I used...
  2. D

    DE filter issue

    Hi, I have been searching here and have not seen an issue similar to mine, so if there is already a thread about this i apologize. I have a Hayward 4800 series DE filter (new home to me, pool is almost 30 years old, and label is gone from filter). I have already replaced the manifold, o-ring...
  3. D

    AquaRite Problem not found elsewhere display reading volts and temp, but not amps or

    Yep, put a new bead on it and am good to go, producing chlorine again. :)
  4. D

    AquaRite Problem not found elsewhere display reading volts and temp, but not amps or

    You guys are so awesome, took off the board and look what I found:
  5. IMG_0308.jpg

    IMG_0308.jpg

  6. D

    AquaRite Problem not found elsewhere display reading volts and temp, but not amps or

    Thanks so much, if the weather holds out tomorrow, I’ll take the board out and look at it and post my findings. Thanks again!
  7. D

    AquaRite Problem not found elsewhere display reading volts and temp, but not amps or

    Thanks, is there more than one relay? Or is it probably something that I will definitely notice? Also, if that was the case, wouldn’t I also see one of the errors that others see when the K1 relay goes bad? (I think it is no flow or no cell power)? Which I don’t see.
  8. D

    AquaRite Problem not found elsewhere display reading volts and temp, but not amps or

    Thanks, I’ll take a look at the board tomorrow, as I have tried the + button already to no avail
  9. IMG_0305.jpg

    IMG_0305.jpg

  10. D

    AquaRite Problem not found elsewhere display reading volts and temp, but not amps or

    Yes, those are the numbers when I have the filter in the on position (Auto) What other diagnostics are you asking for? and no, I get no "no flow" reading, and my Check cell light is not on. That is what makes this case weird to me. I have flow
  11. D

    AquaRite Problem not found elsewhere display reading volts and temp, but not amps or

    OK, I have a problem that I cannot find the answer to. I have an AquaRite system, and the diagnostics read the volts +32.26v but the amps read +0.0A and 0000PPM. I bought a new salt cell T15, installed it, and I get the same thing. Any ideas?